7
Starting
When operating units, the respective and relevant local
guidelines must be observed.
You must also observe these additional instructions:
Only people who have been adequately trained in
operating the units may be placed in charge of their
operation, with monitoring of the containers and cyl-
inder storage.
Make sure that the operator is aware of potential
dangers when handling liquid gas.
The unit may only be installed in well-ventilated
rooms; it may not be installed in residential rooms or
similar spaces!
For optimum unit operation, the device should not be
operated at an ambient temperature above 25 °C.
The unit must be connected to the power supply via
a special supply point with fault current safety
switch.
Make sure to maintain a safe distance to combusti-
ble and flammable materials and comply with local
fire codes.
180°
Connecting the unit to the power supply
1. Set the operating switch to "0".
Off.
2. Plug the unit in to a power socket
with the right connection.
230V/1~ / 10A / 50Hz
3. When connecting the unit to the
power supply, make absolutely sure
that the polarity is correct!
4. If the unit should switch off due to a
malfunction during the start phase,
turn the plug 180°.
1. Plug the supplied bridge circuit plug
2
into the thermostat socket
1
of the
unit.
2. Set the operating switch to "I".
Heating mode.
3. Please note: the air supply fan starts,
the burner controls and monitors the
program automatically.
The flame forms after approx. 15
seconds.
Heating without a room thermostat
The unit runs in continuous operation.
2 1
1. Remove the bridge circuit plug
2
.
2. Plug the thermostat plug
3
of the
room thermostat (accessories) into
the thermostat socket
1
.
3. Put room thermostat
4
in a suitable
place.
The thermostat sensor may not be
placed directly in the warm air
stream or attached to a cold sur-
face.
4. Pre-select desired room tempera-
ture on the room thermostat.
5. Set the operating switch to “I”.
Heating mode.
6. Please note: the air supply fan starts,
the burner controls and monitors the
program automatically.
The flame forms after approx. 15
seconds.
Automatic heating with room thermostat
The unit runs automatically with the temperature which
has been pre-selected on the room thermostat.
1
3
4
Setting and regulating the heat output
1. Set the heat output gradually using the adjustable
“power regulation”.
2. Please note: this setting can also be gradually
changed while the unit is in operation.
Turn to the left:
Increases heat output
Turn to the right:
Lowers heat output
Important Information
Make sure that the air supply can be freely suctioned in
and the heated air blown out.
The unit’s air intakes and outlets may not be constricted
or equipped with hoses or pipes.
Ventilation
In ventilation mode, only the air supply fan runs and the
unit can be used for air circulation.
1. Set operating switch to "II".
2. Please note:
it is not possible to heat!