2
Technical data
2.1 Unit data
Series
MKT 251
MKT 251
Operating mode
Local compact air conditioning unit for cooling
Nominal cooling output
1)
kW
2.60
Energy efficiency ratio - cooling
A
Energy efficiency rating EER
1)
2.63
Energy consumption, hourly
kWh/60 min
0.99
Approx. application area (room volume)
m³
80
Adjustment range indoor unit
°C
+16 to +32
Operating range - indoor unit
°C/%r.F.
+16 to +35 / +35 to +85
Refrigerant
R 410A
3)
Refrigerant, basic capacity
kg
0.5
Max. operating pressure / cooling cycle
kPa
1800 / 3600
Air flow volume per stage
m³/h
240 / 270 / 320
Sound pressure level per stage
2)
dB(A)
49 / 52 / 53
Sound power level max.
dB(A)
62
Power supply
V/Ph/Hz
230 / 1~/ 50
Enclosure class
IP
20
Electr. rated power consumption
1)
kW
0.99
Electr. rated current consumption
1)
A
4.78
Elec. starting current max., LRA
A
17
Exhaust air hose, length / diameter
mm
1500 / 125
Dimensions - height
mm
770
Dimensions - width
mm
435
Dimensions - depth
mm
430
Weight
kg
33.0
Standard colour
white
silver
Serial number
1254...
1255...
EDP no.
1612255
1612256
1)
Room air temperature TK 35
℃
, FK 24
℃
2)
Distance 1m free field
3)
Contains greenhouse gas according to Kyoto protocol
7