background image

11

Fig. no.  Designation

Ref. no.

 

1   Unit bottom 

1106850

 

2   Transport roller 

1106851

 

3   Condensate motor with rotor 

1106852

 

4   Condenser 2.5 µF (evaporator fan)

1106853

 

5   Float regulator (reservoir)  

1106854

 

6   Cover (reservoir) 

1106855

 

7   Microswitch (reservoir) 

1106856

 

8   Compressor, cpl.  

1106857

 

9   Condenser 2.5 µF (compressor) 

1106858

 

10   Evaporator 

1106859

 

11   Fan housing (exhaust air)  

1106860

 

12   Fan wheel (exhaust air)  

1106862

 

13   Fan motor (exhaust air)  

1106863

 

14   Condensate tray  

1106864

 

15   Exhaust air pipe adapter  

1106315

 

16   Condenser 1.5 µF  

1106316

 

17   Evaporator 

1106317

 

18   Fan housing, 3-pc. (circulation air)  

1106318

 

19   Fan wheel, left (circulation air) 

1106869

 

20   Fan wheel, right (circulation air) 

1106870

 

21   Fan motor (circulation air) 

1106871

 

22   Side wall, right  

1106872

 

23   Circuit board 

1106873

 

24   Mains supply line with plug 

1106874

 

25   Front wall 

1106875

 

26   Back wall 

1106876

 

27   Air outlet segment 

1106877

 

28   Side wall, left  

1106878

 

29   PCB with control 

1106879

 

30   Control panel 

1106880

 

31   Entry circuit 

1106881

 

32   Air fi lter 

1106883

 

  Air outlet hose, cpl. (Nos. 33, 34, 35) 

1106885

 

33   Air outlet hose  

1106886

 

34   Connection pipe adapter 

1106887

 

35   Window jet 

1106888

       Not shown   Condensate drain spout with plug 

1106882

       Not shown   Sensor (circulation air) 

1106889

       Not shown   Remote control 

1106884

Spare Part List

When ordering spare parts, enter the serial of the 
device on the rating plate in addition to the Ref. no.

Designation

Ref. no.

Wall bushing 

1613115

(incl. telescopic pipe, protective 

grille, trap, sealing cap) 

Accessories

Summary of Contents for MKT 240

Page 1: ...Timer Functional Principle of the Cooling Process Maintenance and Care Cleaning the Filter Draining the Condensate Trouble Shooting Taking the Device Out of Service Warranty Environment and Recycling...

Page 2: ...lines under carpeting Do not lay lines under carpeting Never operate the device with Never operate the device with out an air lter Never direct the air ow at Never direct the air ow at people Never op...

Page 3: ...ed Observe the following notices Plug the air outlet hose in cluded in delivery onto the air outlet on the rear panel of the device Lock both catches on the air outlet into both openings of the air ou...

Page 4: ...D 14 C F toggle button only on the remote control Operation The device is operated comfortably using the control panel on the device or the in frared remote control Keys with the same symbols have the...

Page 5: ...ed the display switches from the room temperature to the set tempera ture LED 13 lights up and shows the desired temperature for 15 seconds 7 Set the desired room temperature using the Timer Temp Adju...

Page 6: ...porates during operation and is then conducted outside with the exhaust air via the air outlet hose In case of extreme humidity the device collects conden sate in a reservoir If the permissible level...

Page 7: ...and pull the mains plug 2 Place a at tray under the condensate drain spout and remove the plug Fig 17 3 After the condensate has drained reinsert the plug rmly The device is not cooling properly Chec...

Page 8: ...design sub ject to alteration Control panel Evaporator fan Condenser Red Orange Yellow White White W Red Red Red Blue Blue Blue Blue Condenser Condenser Compressor Evaporator fan Reservoir motor Mains...

Page 9: ...480 mm with a diameter of at least 135 mm Take the minimum distance of 430 mm between the oor mounting surface of the device and the centre of the wall bushing into consideration Insert the telescopi...

Page 10: ...of the MKT 240 Technical dimensions and design subject to alteration Device Diagram 28 28 35 35 33 33 34 34 18 18 29 29 19 19 21 31 31 18 18 18 18 20 30 27 25 25 8 1 2 3 10 7 7 6 6 11 5 9 4 23 23 13...

Page 11: ...n wheel right circulation air 1106870 21 Fan motor circulation air 1106871 22 Side wall right 1106872 23 Circuit board 1106873 24 Mains supply line with plug 1106874 25 Front wall 1106875 26 Back wall...

Page 12: ...setting range C 16 bis 32 Temperature operating limits C 16 bis 35 Refrigerant R 407 C Refrigerant quantity kg 0 770 Circulation air volume ow rate m3 h 230 260 300 Exhaust air volume ow rate Max m3...

Reviews: