1.6 Safety instructions for the
operator
The operational safety of the units and compo-
nents is only assured providing they are used as
intended and in a fully assembled state.
n
The units and components may only be set up,
installed and maintained by qualified per-
sonnel.
n
The existing regulations concerning accident
prevention must be adhered to.
n
Do not operate units or components with
obvious defects or signs of damage.
n
Contact with equipment parts or components
can lead to burns or injury.
n
Ensure that electrical energy does not pose a
risk.
n
Regulations of the VDE and the local energy
supply company must be adhered to.
1.7 Safety notes for installation and
inspection tasks
n
The operator must ensure that all inspection
and installation work is carried out by author-
ised and qualified personnel who have thor-
oughly read the operating manual.
n
Work on the system may only ever be carried
out when it is stationary.
n
Appropriate hazard prevention measures must
be taken to prevent risks to people when per-
forming installation, repair, maintenance or
cleaning work on the units.
n
The setup, connection and operation of the
units and its components must be undertaken
in accordance with the usage and operating
conditions stipulated in this manual and comply
with all applicable regional regulations.
n
Regional regulations and laws as well as the
Water Ecology Act must be observed.
n
The power supply should be adapted to the
requirements of the units.
n
The units and components must be kept at an
adequate distance from flammable, explosive,
combustible, abrasive and dirty areas or
atmospheres.
n
Safety devices may not be modified or
bypassed.
1.8 Unauthorised modification and
changes
The operational safety of the supplied units/
components is guaranteed when used in line with
intended use in accordance with section 1.9 of the
operating instructions. Under no circumstances
should the threshold values specified in the data-
sheet be exceeded.
Modifications or changes to units and components
are not permitted and may cause malfunctions.
Safety devices may not be modified or bypassed.
Original replacement parts and accessories
authorised by the manufacturer ensure safety. The
use of other parts may invalidate liability for
resulting consequences.
1.9 Intended use
The buffer tanks are employed for the storage of
hot water in all types of hot water central heating
systems (solid fuel/oil-fired boilers, heat pumps,
solar plant, gas/electric instantaneous water
heaters) within enclosed spaces and for the
storage of cold water for cooling processes or heat
recovery purposes.
Any other or additional use is a non-intended use.
The manufacturer/supplier assumes no liability for
damages arising from a non-intended use. The
user bears the sole risk in such cases. Intended
use also includes working in accordance with the
operating and installation instructions and com-
plying with the maintenance requirements.
The threshold values specified in the technical
data must not be exceeded.
1.10 Warranty
For warranty claims to be considered, it is essential
that the ordering party or its representative com-
plete and return the "certificate of warranty" to
REMKO GmbH & Co. KG at the time when the
units are purchased and commissioned.
The warranty conditions are detailed in the "Gen-
eral business and delivery conditions". Further-
more, only the parties to a contract can conclude
special agreements beyond these conditions. In
this case, contact your contractual partner in the
first instance.