Room climate
Colder/Warmer
can be used to adjust the temper-
ature of the heating (set with the left softkey, then
confirm with "OK"). If the room temperature is too
low, the room thermostat (on the heater) should
first be set higher. If this is not sufficient, then set
the Warmer/Colder value higher by 1 °C. This also
roughly corresponds to one degree of room tem-
perature.
Room climate mode
(select the right softkey, then
confirm with "OK") allows you to define the oper-
ating status of the room heater.
Automatic (recommended): the mode switches
automatically between heating, standby and
cooling (special equipment), based on the outside
temperature. This takes account of the ability of
the building to retain heat. For example, on cooler
summer nights the room heater stays off, pre-
venting unnecessary operation.
Heating: heating mode occurs in accordance with
the outside temperature and the heating curve
(weather-controlled) or in accordance with a fixed
value.
Standby: in standby mode neither heating nor
cooling occurs, however anti-freeze protection is
active.
Cooling: cooling mode occurs in accordance with
the outside temperature and the cooling curve
(weather-controlled) or in accordance with a fixed
value.
Colder / hotter 0,0°C
-10
10
Room climate mode automatic
Fig. 21: Room climate
Then turn the rotary knob clockwise.
One-off hot water/party mode
Activating
Party mode
(select with the right
softkey) causes the next window of time with
reduced heating to be disregarded, so that the
heating runs in normal operation again. After this
period, the heating again functions according to
the stored time program. To activate/deactivate
"One-off hot water" press the left softkey. The
storage tank is enabled for one-off charging (acti-
vated), e.g. for showering outside hot water time
periods).
1 x DHW heating deactivated
Party mode deactivated
Fig. 22: One-off hot water/party mode
Then turn the rotary knob clockwise.
Time programmes
There are 3
user profiles
available for the time
program. For example, Profile A could be used for
early shift weeks, B for late shifts, and C for holi-
days. You can switch profile using the left softkey.
The displayed
time programmes
apply to the cur-
rent day. Blue means reduced mode, red means
normal operation. The current time is displayed
above the time bars.
Time programme for hot water
Time programme for the unmixed heating cycle
Time programme for the mixed heating cycle
The time programmes can be adjusted in the menu
under:
- Settings/Hot water
- Settings/Unmixed heating cycle
- Settings/Mixed heating cycle
You can use the right softkey to activate an "away
period". The system will then function in reduced
mode until the right softkey is pressed again.
REMKO Smart-Control
14