Heating capacity at an inlet temperature of 45 °C
0
5
10
15
20
25
-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
[°C]
[k
W
]
AT
HL
n-max
n-max
n-min
n-min
76/77Hz
NF
Fig. 21: Heating capacity CMF/CMT 160 at an inlet temperature of 45 °C
AT: Outdoor temperature
HL: Heating output
NF: Rated frequency
COP at an inlet temperature of 45 °C
0
1
2
3
4
5
-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
[°C]
AT
76/77 Hz
NF
C
O
P
[-]
Fig. 22: COP CMF/CMT 160 at an inlet temperature of 45 °C
AT: Outdoor temperature
NF: Rated frequency
25