REMKO CLA 100 Operating Instructions Manual Download Page 7

M a i n t en a n ce

 

 

The unit is to be maintained regularly whereby some 
fundamental rules are to be observed to ensure a long 
service life and trouble-free operation. 
 
Use a clean slightly humid cloth for cleaning and wiping 
the dirt off the surface. In case of obstinate dirt only sui-
table cleaning agents should be used. 

 

Prior to starting any work make sure to pull  
the mains plug out of the mains socket! 

 

The unit is to be kept free from dust and other depo-
sits and is to be cleaned only with a dry or humid 
cloth (do not use water jet). 

Do not use any aggressive cleaning agents or those 
which are harmful or environmentally unfriendly. 

Do not use cleaning agents which contain solvents. 

Use only clean fuel oil EL and diesel, respectively 
(make sure to avoid paraffine formation). 

Check oil filters or gas filters regularly and replace 
dirty filters. 

Check whether the unit is free from mechanical da-
mage, if not, replace faulty parts. 

Check fan wings and combustion chamber with heat 
exchanger in regular intervals and clean them when 
they are dirty. 

Check oil tank regularly and clean it when necessary 
to remove dirt and foreign matters. 

Make sure that the waste gas and combustion air 
can be always evacuated properly. 

Check safety devices regularly. 

The unit is to be maintained and cleaned in regular 
intervals. 

Keep feelers of triple combination control always free 
from dust and dirt. 

Have the waste gas values of the oil or gas burner 
checked regularly by authorized experts. 

 
For safety reasons we recommend that you conclude 

maintenance contract!

 

Make sure to store the unit in a dust-free and dry 
place when it is not used for a longer period. 

 

Setting and maintenance is to be carried out only by authorized experts! 

G

 

G

 

Ser v i ce 

 

The complete unit including heat exchanger, 
combustion chamber and oil burner is to be cleaned 
from dust and dirt after every heating period, or even 
earlier, depending on the operational conditions. 
Expendable parts, such as flue gas suppressors, 
gaskets, oil filter inserts, and oil nozzles are to be 
checked and replaced, if necessary. 
 

Heat Exchanger Cleaning

 

 

²

Cut unit from the mains 

 

²

Disassemble connection piece for outgoing air (only 
CLA 25/40/50) 

 

²

In addition CLA 100: 
- disassemble jack ring (pos. 14) 
- disassemble cover plate (pos. 1) 
- disassemble upper insulation (pos. 12) 

 

²

Remove revision cover (pos. 22) 

 

²

Pull flue gas suppressor (pos. 22) out of unit 

 

²

Clean flue gas passes. Special cleaning brushes 
can be obtained as accessories.  

 

²

Clean flue gas suppressor or replace them,  
if necessary. 

 

²

Check gaskets and revision cover and replace,  
if necessary. 

 

²

Assembly is to be carried out in reverse order, 
where-by you should make sure that the gaskets 
and the revision cover is correctly seated. 

 

Combustion Chamber Cleaning

 

 

²

Cut unit from the mains 

 

²

Remove burner 

 

²

Clean combustion chamber through its opening by 
means of a vacuum cleaner. Special cleaning sets 
can be obtained as accessories to the REMKO in-
dustrial vacuum cleaner. 

 

²

Install burner; check flange gasket and replace,  
if necesary. 

 

Make sure that the burner is exclusively maintained 
by authorized experts. 

 

Make sure to observe the limit values for waste gas 
losses according to the regulations for small-sized 
fireplaces. 

G

 

Summary of Contents for CLA 100

Page 1: ...CLA 25 100 Automatic Oil Gas Heater s Edition GB 709 Oper ation Technology Or iginal REMKO Spar e Par ts REMKO alles b r enstar k...

Page 2: ...am 10 Troubleshooting Instructions 11 CLA 25 40 50 CLA 100 G Always keep these operating instructions near or on the device G Mobile oil gas heater s Oper ating instr uctions Make sure to read these i...

Page 3: ...in com pliance with the relevant regulations especially regula tions governing the installation and operation of fire places and furnaces Operators The units may be operated only by persons who have...

Page 4: ...ces Make sure to observe the following safety distances to ensure a safe operation of the unit towards the top without waste gas pipe 3 0 m towards the top fire retarding ceiling 1 5 m towards the sid...

Page 5: ...tch 1 into 0 position OFF Safety Facility Triple combination control according to DIN 3440 The device has 3 functions 1 Fan Control TR The tripping point is set with the adjusting lever fan Rated valu...

Page 6: ...essories which have been approved by our com pany The inside overlappings on the seams of the hot air hoses must run with the air current direction Make sure that the hoses and pipes respectively are...

Page 7: ...ns we recommend that you conclude a maintenance contract Make sure to store the unit in a dust free and dry place when it is not used for a longer period Setting and maintenance is to be carried out o...

Page 8: ...8 CLA 25 40 50 CLA 100 We reserve the right to make modifications in dimensions and construction in the interests of technical progress...

Page 9: ...361 1108151 1108151 1108161 1108355 1108186 1108356 1102550 1102550 1102710 1108362 1108152 1108152 1108162 1108363 1102505 1102505 1102713 1108366 1102506 1102506 1102706 1108367 1108147 1108147 1108...

Page 10: ...180 200 weight without burner kg 110 110 153 260 dimensions length total mm 1385 1385 1685 1955 width total mm 640 640 770 1020 hight total mm 930 930 1030 1240 Dimensions and specifications subject...

Page 11: ...t up if so unlock relay by pressing the anti interference button The burner tries to start take delayed burner start due to oil preheating into account Attention If the burner is switched off once mor...

Page 12: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage Postfach 1827 Telefon 0 52 32 606 0 Telefax 0 52 32 606260...

Reviews: