Connect unit plug (2) to a suitable
mains socket (230V/1 ~ 50Hz).
The unit runs fully automatically with the temperature
which has been preselected on the room thermostat.
Hint!
When the oil burner has been installed by our works, the
heater is equipped with a the standard oil preheating.
Remove the bridge circuit plug (3).
Plug thermostat plug (5) of the room
thermostat (accessories) into the
thermostat socket (4) of switch box.
Put room thermostat (6) in a suitable
place.
The thermostat feeler may not be
exposed directly to the hot air current.
Preselect desired room temperature
on the room thermostat (accessories).
Put the operating switch (1) into “1”
position.
The unit runs in continuous operation.
Plug the supplied bridge circuit plug
(3) into the thermostat socket (4) of
the switch box.
Put the operating switch (1) into “1”
position.
6
4
3
5
4
2
Hot Air Distribution
All the units are equipped with silent and nearly main-
tenance-free axial fans.
Hot air may be distributed only in accordance with the
fan capacity of the units concerned.
The possible hose/pipe lengths depend on the resis-
tance on the air side of the used air ducts. Air is prefer-
rably distributed through pipings or special hot air and
sheet hoses, respectively.
Please observe the following instructions when hot
air hoses are to be fitted:
•
Please use exclusively those hot air hoses
(accessories) which have been approved by our com-
pany.
•
The inside overlappings on the seams of the hot air
hoses must run with the air current direction.
•
Make sure that the hoses and pipes, respectively, are
safely fastened to the unit’s outgoing air connection
piece.
•
The pipes and hoses may not have sharp kinks and
bends in order to avoid heat accumulation.
•
In the case of increased suction temperatures or re-
sis-tance on the unit’s outgoing air side, the burner
can be switched off by the temperature controller
(TW) during the heating operation for a short time.
When the temperature has fallen the burner is restar-
ted automatically.
While the unit is operating, frequent startings of the
burner should be avoided.
When the temperature is too high on the unit’s out-
going air side, the heating-operation is interrupted
automatically for a longer period by the STB!
Attention!
The fan continues running to cool down the combustion
chamber and then stops later.
Never interrupt the connection to the mains before
the end of the whole after-cooling phase (except in
emergency situations).
The fan can start several times before final
switching off!
Our guarantee does not cover damages caused to
the unit by overheating!
Put operating switch (1) into “0” position.
( = OFF)
Close fuel supply.
Sh u t d ow n
G
The connection to the mains of the units is to be carried out in accordance with the VDE
0100 regulations to a special supply point with protection device against faulty current.
G
Heating Without Room Thermostat
Fully Automatic Heating With Room Thermostat