© 2018, Pinnacle Climate Technologies, Inc.
SilentDrive Forced Air Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
Ventilation:
- Risk of indoor air pollution and Carbon
Monoxide Poisoning. Not For Indoor Use.
Indoor use permitted only for the temporary
heating of buildings under construction,
alteration or repair.
- Refer to Safety Information on pages 1-2 for
information about Carbon Monoxide Poisoning.
- ALWAYS
provide a fresh air opening in the heated
space of at least three square feet (2,800 sq. cm) for
each 100,00 Btu/Hr. (29 kW) of heater output. Provide
a larger opening if more heaters are being used.
Minimum Ventilation Opening Needed
REM-150T-SDR-O
REM-220T-SDR-O
5.3 ft.²
6.5 ft.²
3760 cm²
5990 cm²
Starting the Heater: (Ignition)
1. Fill the tank with kerosene or other approved
fuel until needle on fuel gauge points to “F”.
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong
(grounded) power source. You must use a
three prong (grounded) extension cord that
is at least 6 feet long and is a minimum of 14
AWG rating.
4. Press the power button to power on the
heater.
5. Select desired temperature using temperature
+/- buttons.
6. The heater will ignite once the temperature
setting is higher than the ambient
temperature in the space.
Stopping / Restarting Heater:
- To stop the heater, move the power switch to
the “Off” position and unplug the power cord.
- To restart the heater; wait 10 seconds and
follow ignition steps.
Adjusting the Pump Pressure:
- Remove the right side cover (4 screws).
Behind the panel, the pump will have a
brass set screw. Turn screw in quarter turn
increments.
- Clockwise increases the pressure.
- Counterclockwise decreases pressure.
Operation
CARBON
MONOXIDE
POISONING MAY
LEAD TO DEATH!
5
TIP: If the heater does not ignite; press
power button to power off the heater,
check steps 1-3 above and press power
button to power ON the heater.
TIP: If the heater does not ignite, the
thermostat may be set too low. Increase
the temperature to a higher setting until the
heater ignites.
SDR 220 Rating Label + Control Panel
Model - Modelo MH-220T-SDR
COMPLIES WITH UL 733 AND
ANSIA 10.10-1998
CAN/CSA-B140.0-03 AND CSA B140.8-1967
Minimum Distance From Combustibles:
Outlet:
8 ft. (250 cm)
Sides / Top / Rear:
4 ft. (125 cm)
Minimas Distancias de Separacion de Materiales
Combustibles:
Salida de Aire:
8 ft. (250 cm)
Lateral / Superior / Posterior:
4 ft. (125 cm)
BTU/Hr - BTU/h 220,000
Fuel Consumption Gal./Hr.
Consumo de Combustible Gal./h
Fuel Tank Capacity Gal.
Capacidad del Depósito Gal.
V~Hz/Amps - V~Hz/Amperes 120V~60Hz / 3.15
Fuse - Fusible 3.15A
Type of Fuel No. 1 / Kerosene
Tipo de aceite combustible No. 1 / Queroseno
Maximum Air Outlet Temp. °F
Max. Temp. Del Aire De Salida °C
Pump Pressure PSI - Presión de le Bomba 93
Phase - Fase 1Ø
1.67
13
1025
552
© 2017 Pinnacle Climate Technologies, Inc.
www.masterindustrialproducts.com
Made In China
Hecho en China
See Operating Instructions and Troubleshooting on
side panel.
Las instrucciones de Funcionamiento y soluciónes
de problemas se encuentran en el panel lateral.
°F
°F
MASB-004
Figure 3
DANGER