background image

Model Numbers

REM-45-KFA-O / REM-75T-KFA-O / REM-135T-KFA-O / REM-175T-KFA-O / REM-190T-KFA-O 

REM-215T-KFA-O

CONSUMER: READ AND SAVE THESE INSTRUCTIONS

GENERAL HAZARD WARNING: READ AND UNDERSTAND 

ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE 

ASSEMBLING, STARTING, OR SERVICING THE HEATER. 

Be sure to comply with the instructions and warnings provided with this heater. Failure to 

comply can result in fire or explosion that can cause property loss, bodily injury, or loss 

of life. Only persons who can follow and understand these instructions should operate or 

service this heater. If you need heater info; such as an operating manual, labels, etcetera, 

contact Pinnacle Climate Technologies at 866-676-1989.

DANGER

NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN 

ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION. 

FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY 

FOR:

 

THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS 

OR STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. 

This is an 

unvented portable heater that uses air (Oxygen) from within the area in which it is used.  

Failure to provide adequate combustion and ventilation air will result in asphyxiation, carbon 

monoxide poisoning, bodily injury or death. Refer to “Ventilation” on Page 5.

FACTORY ID: 001

Safety Information

FIRE, BURN, INHALATION AND EXPLOSION HAZARD. 

Keep 

combustibles such as; building materials, paper or cardboard a 

safe distance away from the heater as recommended by these 

instructions. Never use the heater in spaces which contain products such as; gasoline, 

solvents, paint thinners, dust particles, volatile or airborne combustibles or any unknown 

chemicals. This is an unvented portable heater. It uses air (Oxygen) from the area in which 

it is used. Adequate combustion and ventilation air must be provided. Refer to “Ventilation” 

on page 5. Bulk fuel storage should be a minimum of 25 feet from heater.

WARNING

DO NOT OPERATE THIS HEATER UNTIL 

YOU HAVE READ AND THOROUGHLY 

UNDERSTAND THESE SAFETY AND 

OPERATING INSTRUCTIONS.

Failure to comply with the precautions and instructions provided with this 

heater can result in death, serious bodily injury, property loss or damage 

from the hazards of fire, soot production, explosions, burns, asphyxiation or 

carbon monoxide poisoning. Only persons who can read and understand 

these instructions should use or service this heater

DANGER

WARNING

1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989

Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: [email protected]

© 2017 Pinnacle Climate Technologies, Inc. RGKD-401

User’s Manual & 

Operating Instructions

KEROSENE FORCED AIR 

HEATER

Summary of Contents for REM-135T-KFA-O

Page 1: ...to Ventilation on Page 5 FACTORY ID 001 Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heate...

Page 2: ...use for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98...

Page 3: ...ls away from this heater Minimum Clearance From Combustibles 45 190T KFA 215T KFA Top 4 ft 4 ft Sides 4 ft 4 ft Front 8 ft 10 ft ALWAYS locate heater on a stable and level surface If your heater is eq...

Page 4: ...Manual 3 Wiring Diagrams 45 KFA 75T 215T KFA Assembly Instructions What s In The Box Models 45 KFA 75T KFA Remove the heater and all packaging materials from the shipping carton Note Save the box and...

Page 5: ...lace heater on wheel support and line up holes on the fuel tank lip 5 Attach front handle with 2 long screws 50 mm and 2 nuts through the second hole from the front on both sides of the tank lip and w...

Page 6: ...R use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should only be stored in a blue contain...

Page 7: ...temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F the display says HI Between 0 F and 99 F the display s...

Page 8: ...starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fuel...

Page 9: ...ESSURE While heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 75T KFA...

Page 10: ...proper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh kerose...

Page 11: ...POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 10 14 11 13 8 12 9 30 26 3 16 2 4 6 1 7 22 24 17 18 19 21 30 20 15 41 33 35 36 29 28 5 32 31 25 27 38 37 3...

Page 12: ...21 0510 70 021 0520 70 021 0520 18 Pump Body 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 19 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 20 End Pump Cover 70 0...

Page 13: ...If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Reviews: