NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

Troubleshooting Guide

Problem

Possible Cause

Solution

Heater Ignites, but main PCB shuts 

off after a short period of time. 

Lamp flickers and LED display 

shows “E1”.

1.  Incorrect pump pressure.

2. 

Dirty input, output or lint filter.

3. 

Dirty fuel filter.

4.  Nozzle is dirty.

5.  Photocell lens is dirty.

6.  Photocell not installed properly.

7.  Photocell is defective.

8.  Improper electrical connection 

between main PCB and photocell.

9.  Improper location of thermister sensor 

(does not apply to 45-KFA model)

10.  Improper electrical connection within 

the temperature limit switch

1.  Adjust pump pressure.

2. 

Clean / replace air or lint filter.

3. 

Clean / replace fuel filter.

4.  Clean / replace Nozzle.

5.  Clean / replace photocell.

6.  Adjust photocell position

7.  Replace photocell

8.  Check wiring connections  

(see wiring diagrams on page 3).

9.  Check thermister placement

10. Replace temperature limit switch

Heater will not operate or motor 

runs for a short time.

Lamp flickers and LED display 

shows “E1”.

1.  No kerosene in the fuel tank.

2.  Incorrect pump pressure.

3.  Corroded spark plug or incorrect 

plug gap.

4. 

Dirty fuel filter.

5.  Dirty nozzle.

6.  Moisture in fuel tank. 

7.  Improper electrical connection 

between transformer and circuit 

board.

8.  Ignitor wire not connected to spark 

plug.

9.  Defective ignitor. 

10. Improper spacing with rotor

1.  Fill tank with fresh kerosene.

2.  Adjust pump pressure.

3.  Clean / replace spark plug. 

4. 

Clean / replace fuel filter. 

5.  Clean / replace nozzle.

6.  Rinse fuel tank with clean, fresh 

kerosene.

7.  Inspect all electrical connections. 

(See wiring diagrams on page 3.) 

8.  Re-attach ignitor wire to spark plug. 

9.  Replace ignitor.  

10. Adjust rotor

Fan does not operate when heater 

is plugged in and power switch is 

in the “ON” position. The lamp is 

flickering or and LED display shows 

“E1” or “E2”.

1.  Thermostat is set too low (does not 

apply to 45-KFA model).

2.  Broken electrical connection 

between main PCB and motor. 

1.  Rotate thermostat to a higher 

setting

2.  Inspect all electrical connections 

(see wiring diagrams on page 3).

Lamp is flickering and LED display 

shows “E3”.

1.  Thermostat switch has failed.

1.  Replace thermostat switch (see 

Wiring diagrams on page 3).

Poor combustion and / or excess 

soot production. 

1. 

Dirty input, output or lint filter.

2. 

Dirty fuel filter.

3.  Poor quality of fuel.

4.  PSI is too high or too low. 

5.  Dirty nozzle

1. 

Clean / replace air or lint filter.

2. 

Clean / replace fuel filter.

3.  Flush fuel tank and refuel heater.

4.  Use proper pressure. 

5.  Clean / replace nozzle

Heater does not turn on and the 

lamp is not lit.

1.  Temperature limit sensor has 

overheated. 

2.  No electrical power.

3.  Fuse is blown.

4.  Improper electrical connection 

between temperature limit sensor 

and circuit board. 

1.  Push power switch to “OFF and 

allow heater to cool for 10 minutes. 

Restart heater. 

2.  Check power cords for proper 

connection and test the power 

supply.

3.  Check / replace the fuse.

4.  Inspect all electrical connections 

(see wiring diagrams on page 3).

9

Summary of Contents for REM-135T-KFA-O

Page 1: ...to Ventilation on Page 5 FACTORY ID 001 Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heate...

Page 2: ...use for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98...

Page 3: ...ls away from this heater Minimum Clearance From Combustibles 45 190T KFA 215T KFA Top 4 ft 4 ft Sides 4 ft 4 ft Front 8 ft 10 ft ALWAYS locate heater on a stable and level surface If your heater is eq...

Page 4: ...Manual 3 Wiring Diagrams 45 KFA 75T 215T KFA Assembly Instructions What s In The Box Models 45 KFA 75T KFA Remove the heater and all packaging materials from the shipping carton Note Save the box and...

Page 5: ...lace heater on wheel support and line up holes on the fuel tank lip 5 Attach front handle with 2 long screws 50 mm and 2 nuts through the second hole from the front on both sides of the tank lip and w...

Page 6: ...R use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should only be stored in a blue contain...

Page 7: ...temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F the display says HI Between 0 F and 99 F the display s...

Page 8: ...starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fuel...

Page 9: ...ESSURE While heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 75T KFA...

Page 10: ...proper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh kerose...

Page 11: ...POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 10 14 11 13 8 12 9 30 26 3 16 2 4 6 1 7 22 24 17 18 19 21 30 20 15 41 33 35 36 29 28 5 32 31 25 27 38 37 3...

Page 12: ...21 0510 70 021 0520 70 021 0520 18 Pump Body 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 19 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 20 End Pump Cover 70 0...

Page 13: ...If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Reviews: