background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

11

Parts List

TIP: To order parts call 866-676-1989.

#

Description

45-KFA

75T-KFA

135T-KFA

175T/190T-KFA

215T-KFA

1

Drain Plug

70-002-0105

70-002-0105

70-002-0105

2

Fuel Gauge

70-007-0110

70-007-0115

70-007-0210

70-007-0210

70-007-0215

3

Fuel Filter

70-003-0100

70-003-0100

70-003-0200

70-003-0200

70-003-0200

4

Fuel Cap - Large Plastic

70-006-0140

70-006-0140

70-006-0140

70-006-0140

70-006-0140

5

Power Cord

70-034-0100

70-034-0100

70-034-0200

70-034-0200

70-034-0200

6

Power Switch

70-038-0100

70-038-0100

70-038-0100

70-038-0100

70-038-0100

7

Thermostat Control Knob

70-031-0100

70-031-0100

70-031-0100

70-031-0100

8

Air Line

70-035-0100

70-035-0200

70-035-0300

70-035-0400

70-035-0500

9

Thermostat Limit Control

70-019-0100

70-019-0100

70-019-0100

70-019-0100

70-019-0200

10

Combustion Chamber Assembly

70-011-0100

70-011-0200

70-011-0300

70-011-0400

70-011-0500

11

Photocell Bracket

70-010-1010

70-010-1010

70-010-1010

70-010-1010

70-010-1010

12

Fuel Line

70-036-0100

70-036-0200

70-036-0300

70-036-0400

70-036-0500

13

Photocell

70-016-0100

70-016-0100

70-016-0100

70-016-0100

70-016-0100

14

Burner Head Assembly

70-014-0101

70-014-0101

70-014-0301

70-014-0401

70-014-0401

15

Nozzle Kit

70-015-0100

70-015-0210

70-015-0310

70-015-0410

70-015-0500

16

Spark Plug Kit

70-052-0100

70-052-0100

70-052-0200

70-052-0200

70-052-0200

17

Motor

70-021-0500

70-021-0500

70-021-0510

70-021-0520

70-021-0520

18

Pump Body

70-020-0101

70-020-0101

70-020-0101

70-020-0401

70-020-0401

19

Rotor Kit

70-022-0100

70-022-0100

70-022-0100

70-022-0200

70-022-0200

20

End Pump Cover

70-020-0102

70-020-0102

70-020-0102

70-020-0102

70-020-0102

21

Filter Kit

70-054-0100

70-054-0100

70-054-0100

70-054-0100

70-054-0100

22

End Filter Cover

70-020-0103

70-020-0103

70-020-0103

70-020-0103

70-020-0103

23

Pump Adjustment Kit

70-055-0100

70-055-0100

70-055-0100

70-055-0100

70-055-0100

24

Capacitor

70-020-0125

70-020-0125

70-020-0200

70-020-0201

70-020-0201

25

Fan

70-024-0100

70-024-0200

70-024-0300

70-024-0400

70-024-0400

26

Ignitor

70-037-0350

70-037-0350

70-037-0350

70-037-0350

70-037-0350

27

Fan Guard

70-016-0700

70-016-0700

70-016-0200

70-016-0200

70-016-0220

28

Main PCB Assembly

70-027-0110

70-027-0200

70-027-0310

70-027-0310

70-027-0310

29

Fuse

70-027-0101

70-027-0101

70-027-0101

70-027-0101

70-027-0101

30

Clip Nut

70-001-0105

70-001-0105

70-001-0105

70-001-0105

70-001-0105

31

Air Pressure Gauge

70-025-0100

70-025-0100

70-025-0100

70-025-0100

32

Cord Bushing

70-033-0100

70-033-0100

70-033-0200

70-033-0200

70-033-0200

33

Handle

70-001-0103

70-001-0103

34

Front Handle

70-042-0100

70-042-0200

70-042-0200

35

Rear Handle

70-043-0105

70-043-0205

70-043-0205

36

Wheel Support Frame

70-041-0101

70-041-0201

70-041-0201

37

Wheel Axle

70-041-0115

70-041-0205

70-041-0205

38

Wheel

70-041-1400

70-041-1400

70-041-1400

39

Wheel Nut

70-041-0550

70-041-0550

70-041-0550

40

Hardware Kit (not pictured)

70-056-0100

70-056-0100

70-056-0200

70-056-0200

70-056-0200

41

Cord Wrap

70-032-0100

70-032-0100

70-032-0200

70-032-0200

70-032-0200

42

Motor Supporter

0-020-0600

70-020-0600

70-020-0610

70-020-0610

70-020-0610

Summary of Contents for REM-135T-KFA-O

Page 1: ...to Ventilation on Page 5 FACTORY ID 001 Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heate...

Page 2: ...use for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98...

Page 3: ...ls away from this heater Minimum Clearance From Combustibles 45 190T KFA 215T KFA Top 4 ft 4 ft Sides 4 ft 4 ft Front 8 ft 10 ft ALWAYS locate heater on a stable and level surface If your heater is eq...

Page 4: ...Manual 3 Wiring Diagrams 45 KFA 75T 215T KFA Assembly Instructions What s In The Box Models 45 KFA 75T KFA Remove the heater and all packaging materials from the shipping carton Note Save the box and...

Page 5: ...lace heater on wheel support and line up holes on the fuel tank lip 5 Attach front handle with 2 long screws 50 mm and 2 nuts through the second hole from the front on both sides of the tank lip and w...

Page 6: ...R use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should only be stored in a blue contain...

Page 7: ...temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F the display says HI Between 0 F and 99 F the display s...

Page 8: ...starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fuel...

Page 9: ...ESSURE While heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 75T KFA...

Page 10: ...proper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh kerose...

Page 11: ...POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 10 14 11 13 8 12 9 30 26 3 16 2 4 6 1 7 22 24 17 18 19 21 30 20 15 41 33 35 36 29 28 5 32 31 25 27 38 37 3...

Page 12: ...21 0510 70 021 0520 70 021 0520 18 Pump Body 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 19 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 20 End Pump Cover 70 0...

Page 13: ...If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Reviews: