background image

TREATMENT

4.     Press the Flash Button to deliver a flash. 
• Mild to moderate discomfort is normal. If a flash delivered  
   at Energy Level 1 feels tolerable, increase to Energy Level  
   2. Move the device to a different spot and ash the  
   i-LIGHT

®

 one more time. Repeat this process until you and 

   the setting that feels right for you. 
• Wait 24 hours and then look at the test area. If the skin appears normal, proceed with  
   your first full treatment at the energy level you determined is right for you.

NOTE:

 You must test the device on each area of the face or body you wish to treat. 

Changing Attachments

• Your i-LIGHT

®

 PRO Face & Body comes with two 

   separate attachments for the face and body. 
• The Body Attachment Cap is specially designed for 
   body hair and can flash every 3 seconds. 
• The Facial Attachment Cap is specially tuned for female facial hair and minimises light  
   leakage, it can flash every 4 seconds.
• The attachments are marked with different icons to identify them (Fig 15).

To Change Attachments:

WARNING:

 Always ensure the unit is OFF and the power cord is disconnected before 

removing the attachment.
• If the attachment is removed while the unit is powered ON, all indicator lights on the 
base unit will ash and audible “beeps” will sound.
• Allow the system to cool down for 5 minutes before attempting to change attachments. 
1.  Turn the Power Switch OFF and unplug the Power Cord from the electrical outlet.

16

3  Press the Flash Button to deliver a flash. 

•  Mild to moderate discomfort is normal. If a flash delivered at Energy Level 1 feels tolerable, increase to  

 

Energy Level 2. Move the device to a different spot and flash the i-LIGHT® one more time. Repeat this  

 

process until you find the setting that feels right for you. 

•  Wait 24 hours and then look at the test area. If the skin appears normal, proceed with your first full  

 

treatment at the energy level you determined is right for you. 

,

  NOTE: You must test the device on each area of the face or body you wish to treat.

 

 

TREATMENT 

 

CHANGING ATTACHMENTS 

 

Your i-LIGHT® comes with two separate attachments for the face and body. 

•  The Body Attachment is specially designed for body hair and can flash every 3 seconds.  

•  The Facial Attachment is specially tuned for Female Facial Hair and minimises light leakage, it can flash  

 

every 4 seconds.  

•  The attachments are marked with different icons to identify them (Fig. 8) 

,

  To change attachments: 

,

 

WARNING: Always ensure the unit is OFF and the power cord is disconnected before removing the  

 

attachment.  

•  If the attachment is removed while the unit is powered ON, all indicator lights on the base unit will  

 

flash and audible “beeps” will sound. 

•  Allow the system to cool down for 5 minutes before attempting to change attachments. 

1  Turn the Power Switch OFF and unplug the Power Cord from the electrical outlet. 

2  Hold the attachment with one hand while pressing both Attachment Release Buttons with the other  

 

hand and pull gently (Fig. 9).  

3  Gently push the other attachment back into the Hand Piece making sure both side tabs click into   

 

place.  

,

  NOTE: the longer tab (with gold circuits) must be on top to properly fit. 

Fig. 8

Fig. 7

3  Press the Flash Button to deliver a flash. 

•  Mild to moderate discomfort is normal. If a flash delivered at Energy Level 1 feels tolerable, increase to  

 

Energy Level 2. Move the device to a different spot and flash the i-LIGHT® one more time. Repeat this  

 

process until you find the setting that feels right for you. 

•  Wait 24 hours and then look at the test area. If the skin appears normal, proceed with your first full  

 

treatment at the energy level you determined is right for you. 

,

  NOTE: You must test the device on each area of the face or body you wish to treat.

 

 

TREATMENT 

 

CHANGING ATTACHMENTS 

 

Your i-LIGHT® comes with two separate attachments for the face and body. 

•  The Body Attachment is specially designed for body hair and can flash every 3 seconds.  

•  The Facial Attachment is specially tuned for Female Facial Hair and minimises light leakage, it can flash  

 

every 4 seconds.  

•  The attachments are marked with different icons to identify them (Fig. 8) 

,

  To change attachments: 

,

 

WARNING: Always ensure the unit is OFF and the power cord is disconnected before removing the  

 

attachment.  

•  If the attachment is removed while the unit is powered ON, all indicator lights on the base unit will  

 

flash and audible “beeps” will sound. 

•  Allow the system to cool down for 5 minutes before attempting to change attachments. 

1  Turn the Power Switch OFF and unplug the Power Cord from the electrical outlet. 

2  Hold the attachment with one hand while pressing both Attachment Release Buttons with the other  

 

hand and pull gently (Fig. 9).  

3  Gently push the other attachment back into the Hand Piece making sure both side tabs click into   

 

place.  

,

  NOTE: the longer tab (with gold circuits) must be on top to properly fit. 

Fig. 8

Fig. 7

Fig 14

Fig 15

Summary of Contents for i-Light Pro+ Face & Body IPL6500BAU

Page 1: ...2 YEAR WARRANTY IPL6500BAU...

Page 2: ......

Page 3: ...skin white grey or very light blonde red hair For facial use Only suitable for female facial use below the cheekbone DO NOT use on or around the eyes eyebrows or eyelashes Doing so can cause serious a...

Page 4: ...sure the power cable and adaptor do not get wet Do not reach for your unit if it has fallen into water immediately unplug it from the electrical outlet 11 Do not plug or unplug the appliance with wet...

Page 5: ...eye injury Skin Type DO NOT use on very dark or black skin as it may result in burns blisters and changes in skin colour DO NOT use on tanned skin or after recent sun exposure as it may cause burns or...

Page 6: ...pen wounds cold sores sunburns or areas where you have had a skin peel or other skin resurfacing procedure within the last 6 8 weeks DO NOT use on irritated skin including rashes or swollen skin These...

Page 7: ...se directly over or near Active Implantable Medical Devices such as implantable pacemakers internal defibrillators or insulin devices Although no problems associated with the use of this device have b...

Page 8: ...i LIGHT PRO FACE BODY KEY FEATURES 8 i LIGHT KEY FEATURES Figure1 20 19 1 18 10 11 17 12 13 14 2 3 4 4 5 6 7 8 9 16 12 15 14 4 13 13...

Page 9: ...and Piece Cord 12 Flash Window 13 Skin Contact Sensors 14 Attachment Release Buttons 15 Bulb 16 Body Attachment 17 Power Cord 18 Lint Free Cloth 19 Facial Attachment Be patient when first using your i...

Page 10: ...ilises similar clinically proven technology that professional dermatologis optimised for personal treatment What is Intense Pulse Light IPL and how does i LIGHT work IPL Intense Pulsed Light is a well...

Page 11: ...to continue with the full treatment regime and top up treatments to ensure that every active hair is treated Treatment Regime A full treatment regime is once every two weeks for three treatments Indi...

Page 12: ...RNING always inspect the Flash Window before use to ensure there is no damage to the lens WARNING always clean the Flash Window before use with the lint free cloth provided to ensure there is no oil o...

Page 13: ...eas such as cheeks sideburns chin neck area and above the lips It can also be used on other smaller areas such as the under arms and bikini area Fig 9 Flash Button The Flash Button is located on the h...

Page 14: ...If your skin is suitable you will hear a beep and the i LIGHT will switch on If your skin is unsuitable you will hear a buzz and the i LIGHT will remain switched off NOTE You must use the skin sensor...

Page 15: ...equipped with 5 energy levels Level 1 is the lowest setting an setting TIP For the most effective results always use the highest energy level that do on the skin To determine the energy level being u...

Page 16: ...minimises light every 4 seconds The attachments are marked with different icons to identify them Fig 8 To change attachments WARNING Always ensure the unit is OFF and the power cord is disconnected b...

Page 17: ...grid like pattern to ensure full coverage of the treatment area For Single Flash Mode press the Flash Button each time you move to the next area Store the unused attachment in a safe location such as...

Page 18: ...atment For best results avoid overlapping flashes This helps prevent exposure to more energy than is necessary to suppress hair growth It also ensures that you get the maximum use of the bulb For the...

Page 19: ...for better skin contact the contours of the skin may make it difficult for the skin contact sensors to be fully depressed in certain areas You may find it easier to try and wrap your upper lip over y...

Page 20: ...ith i LIGHT as this section addresses the most common problems you could encounter with i LIGHT If you have followed the instructions in this section and continue to experience problems please contact...

Page 21: ...uide if you experience any problems with i LIGHT PRO Face Body as this section addresses the most common problems you could encounter with the i LIGHT PRO Face Body If you have followed the instructio...

Page 22: ...ment The treated areas become red after treatment This is normal and the redness should subside If not try using a lower energy level BE AWARE If the unit is used over an extended period of time the u...

Page 23: ...ody Is it safe A i LIGHT PRO Face Body is clinically proven to be safe effective but like any electronic device it is important that you read and follow the operating instructions and safety warnings...

Page 24: ...e event that you need to dispose of your i LIGHT PRO Face Body device to ensure proper disposal of the product please take the appliance to a recycling centre where the battery should be removed by a...

Page 25: ......

Page 26: ...end user purchaser of the Goods 1 Our goods come with guarantees that cannot be excluded under the Australian Consumer Law or the CGA You are entitled to a replacement or refund for a major failure an...

Page 27: ...and from the Supplier or us 12 This warranty is only valid and enforceable in Australia against Spectrum Brands Australia Pty Ltd and in New Zealand against Spectrum Brands New Zealand Limited Warran...

Page 28: ...further details Spectrum Brands Australia Pty Ltd Locked Bag 3004 Braeside VIC 3195 Australia Customer service in Australia 1800 623 118 E mail consumer enquiry remington products com au Website www...

Reviews:

Related manuals for i-Light Pro+ Face & Body IPL6500BAU