UNPACKING AND TESTING APPLIANCE
Carefully remove t he appliance from t he box. Prior to inst alling t he appliance, t est t o make sure t he
appliance operat es properly by plugging t he power supply cord int o a convenient ly located 120 Volt
grounded out let .
GROUNDING APPLIANCE
This appliance is for use on 120 Volt s. The cord has a plug as show n in (A). An adapt er as show n in (C)
is available for connect ing t hree-blade grounding t ype plugs t o t wo-slot receptacles. The green
grounding lug ext ending from t he adapt er must be connect ed t o a permanent ground such as a
properly grounded out let box. The adapt er should not be used if a t hree-slot grounded receptacle is
available.
To disconnect appliance, t urn cont rols to off, t hen remove plug from out let .
LOCATING THE FIREPLACE
Plan w here to locat e and frame t he fireplace. This w ill save t ime and money lat er w hen you inst all
t he fireplace. Before installat ion consider t he follow ing:
1.
Where t he fireplace is locat ed must allow for wall and ceiling clearances (see
INSTALLATION
)
2.
Consider a locat ion w here t he fireplace screen w ill not be exposed t o direct sunlight from
w indows or doors.
3.
A 15 ampere, 120 Volt , 60 Hz branch circuit w it h proper ground must be available at t he locat ion.
Preferably a dedicat ed branch circuit should be provided t o avoid circuit breakers t o t rip of fuses
t o blow.