background image

24

Remeha P 520

29/08/05 - 300003791-001-B

87

8259-8014

Lower front crosspiece

88

8555-8515

Fastening bracket for front side pane

89

8259-8818

Complete lower front side panel

90

200002992

Complete upper front panel

91

8555-8517

Complete lower front panel

92

8555-8518

Upper rear panel

93

8259-8021

Lower left-hand rear panel

94

8259-8022

Lower right-hand rear panel

95

8259-0518

Panel for furnace door

96

8555-8519

Control panel trim

97

8555-8520

Rear cover for standard control panel

98

8555-8521

Control panel bracket

99

8259-8055

Lower rear crosspiece

100

8555-8522

Upper crosspiece

101

8555-8526

Intermediate upper crosspiece

102

8555-8082

Joining central plate

103

8555-8523

Lower tab of rail

104

8555-8022

Upper bracket

105

8555-0526

Upper front crosspiece

106

9532-0780

Ring

107

9775-8859

Rapid nut

108

8555-8525

Fasteners for common parts

Front side casing

110

8555-8598

front side panel 800 mm

110

8555-8599

front side panel 940 mm 

110

8555-8616

front side panel 1050 mm 

111

8555-8514

Fasteners for front side panel

112

8555-8507

right-hand upper front plate for sweeping 
800 mm

112

8555-8508

right-hand upper front plate for sweeping 
940 mm 

112

8555-8509

right-hand upper front plate for sweeping 
1050 mm 

112

8555-8510

left-hand upper front plate for sweeping 
800 mm

113

8555-8511

left-hand upper front plate for sweeping 
940 mm

113

8555-8512

left-hand upper front plate for sweeping 
1050 mm

Rear side casing

114

8555-8500

rear side panel 400 mm

114

8555-8501

rear side panel 600 mm 

115

8555-8513

Fasteners for rear side panel

116

8555-8505

upper rear plate for sweeping 400 mm

116

8555-8506

upper rear plate for sweeping 600 mm

Markers

Code no.

Description

Control panel K - RC 1

Refer to the Spare Parts list in the panel 
instructions.

Markers

Code no.

Description

Summary of Contents for P 520-13

Page 1: ...Remeha P 520 Fuel oil gas boilers Technical instructions English 29 08 05 63115...

Page 2: ...heating circuit 11 3 Filling the system 12 4 Sludge removal 12 Chimney connection 13 1 Flue size 13 2 Chimney connection 13 Fuel oil or gas connections 14 Electrical connections 14 Maintenance 14 1 S...

Page 3: ...r tanks are designed and manufactured in accordance with the sound engineering practice as requested in article 3 3 of the directive 97 23 EC it is certified by compliance with the directives 90 396 E...

Page 4: ...ed for connecting to a flue pipe which require a separate automatic fuel oil or gas burner The useful power of P 520 boilers is between 754 and 1450 kW Models available Boiler with control panel which...

Page 5: ...r input kW 773 to 838 902 to 967 1031 to 1096 1160 to 1224 1289 to 1353 1418 to 1482 1547 to 1611 Number of sections 13 15 17 19 21 23 25 Water capacity l 617 693 769 845 943 1019 1095 Water resistanc...

Page 6: ...M H K E L G P D T E 223 300 100 C 741 1172 M000032 718 A 50 1 2 3 755 Boiler P 520 P 520 13 P 520 15 P 520 17 P 520 19 P 520 21 P 520 23 P 520 25 A mm 1563 1785 2007 2229 2491 2713 2935 B mm 1522 1744...

Page 7: ...7 29 08 05 300003791 001 B Remeha P 520 Main dimensions Rear view P 520 565 3 4 500 Max 700 max 610 M000158...

Page 8: ...nnection not supplied 1 In order to facilitate subsequent work on the boiler replacing the water distributing tube etc use a flanged connection from the boiler to the system making sure you comply wit...

Page 9: ...e particularly corrosive These compounds are present for example in aerosol sprays paints solvents cleaning products washing products detergents glues snow clearing salts etc Therefore Do not suck in...

Page 10: ...59 6 weld Heating outlet 13 to 17 sections 139 7 5 18 to 25 sections 159 6 weld dimension without connection see figure on chapter Boiler location straight or angled connection C 1080mm H D M000034 1...

Page 11: ...recycle flow in the boiler Maximum water flow Qmax 0 86 Pn 5 Qn flow in m3 h Pn Nominal output full boiler output in kW Operation in cascade After stopping the burner Timeout required before the orde...

Page 12: ...which opens out onto the air the system must include manual bleeder valves in addition to automatic bleeder valves with the capability to bleed the system by themselves when it is operating the manual...

Page 13: ...ecial sealing precautions have been taken for instance in order to connect a static condenser regenerator 2 Chimney connection The connection shall be removable and offer minimum load losses i e it mu...

Page 14: ...Sweeping The boiler will only operate efficiently if the exchange surfaces are kept clean The boiler should be cleaned as soon as required and as the chimney at least once a year or more depending upo...

Page 15: ...sweeping covers Remove the sweeping covers Remove the left and right hand casing covers Remove the top insulating material Brush the vertical plates Put back the sweeping covers insulating material an...

Page 16: ...flue ways with a vacuum cleaner Close the lower sweeping doors Put back the front casing panels by reversing the removal procedure Unfasten the wing nuts and remove the lower left and right hand sweep...

Page 17: ...utions required if the heating is stopped when there is a risk of freezing We recommend the use of a correctly dosed antifreeze agent to prevent to the heating circuit from freezing If this cannot be...

Page 18: ...plate The identification plate fixed on the side of the boiler during installation is used to identify the boiler correctly and also provides the main specifications of the boiler Boiler type Power ra...

Page 19: ...reference number next to the part required 13 04 05 300003791 002 A Boiler body M000049 44 21 19 38 39 2a 22 43 47 37 20 29 28 31 52 30a 16 46 46 40 39 39 46 39 40 15 46 11 13 33 45 60 61 63 30 25 23...

Page 20: ...Insulation 71 70 M000050...

Page 21: ...300003791 001 B Remeha P 520 Boiler casing 89 103 91 89 90 95 113 85 97 84 114 110 99 84 100 92 93 116 86 102 96 105 98 88 116 112 110 94 100 101 83 82 88 104 81 80 87 104 103 80 106 114 108 111 115...

Page 22: ...22 x 170 x 4 22 8112 0028 Plug 2 23 8008 8904 Flange with outlet piece Gasket 13 to 17 sections 23 8008 8905 Flange with outlet piece Gasket 19 to 25 sections 24 8008 8922 Nozzle Gasket 26 8008 8908 F...

Page 23: ...8555 8011 rail 1565 mm 80 8555 8012 rail 1675 mm 80 8555 8013 rail 1765 mm 80 8555 8014 rail 1875 mm 80 8555 8015 rail 2025 mm 80 8555 8016 rail 2165 mm 80 8555 8017 rail 2275 mm 80 8555 8018 rail 23...

Page 24: ...775 8859 Rapid nut 108 8555 8525 Fasteners for common parts Front side casing 110 8555 8598 front side panel 800 mm 110 8555 8599 front side panel 940 mm 110 8555 8616 front side panel 1050 mm 111 855...

Page 25: ...Remeha P 520 29 08 05 300003791 001 B...

Page 26: ...Remeha P 520 29 08 05 300003791 001 B...

Page 27: ...Remeha P 520 29 08 05 300003791 001 B...

Page 28: ...el 34 3 3000204 Fax 34 3 3009558 E Cuatrocesa S A c Sor Angela de La Cruz 10 1 Oficina C 28020 MADRID Tel 34 91 658 18 88 Fax 34 91 658 30 77 E D A C S A Tom s A Edison 29 Poligono Cogullada 50014 ZAR...