DECORATOR IN-WALL SPRING WOUND TIMER

INSTRUCTIONS

CONTENTS

Rating: 20 A, 125 V  general use

10 A, 250 V  general use

10 A, 277 V  general use

125VAC,1,875 W tungsten, 15 A resistive

1 HP, 125 V AC

2 HP, 250 V AC

125 VAC, 500 W electronic ballast

SAVE THESE INSTRUCTIONS!

  

SAFETY INFORMATION

Timer

Wire nuts

Mounting screws

(Wall box - 0.748 in.)

Mounting screws

(Wall plate - 0.33 in.)

To avoid fire, shock, or death, turn off power at circuit breaker and test that power is off before wiring.

Please read and understand this entire manual before attempting to assemble, operate or install the product. 

Installation by a licensed electrician is recommended. Installation and use of this equipment should be in accordance with 

provisions of the U.S. National Electrical Code, applicable local codes and pertinent industry standards. These timers are

not to be used in precision timing applications when inaccurate timing could have dangerous consequences such as with

sun lamps or in tanning booths.

• Do not use to control receptacles.

• For indoor use only unless installed in a, NEMA type 3R enclosure.

• Use only copper wire.

• High Voltage – Disconnect power supply before servicing.

• The device is to be used in conjunction with a UL Listed Cover Plate for field installation.

• 

Store indoors in dry location.

CAUTION

2. Installation 

  1. Turn OFF power at the main in-wall junction box.

  2. Remove current wall plate and current switch from vertically installed wall box.

  3. Using the provided wire nuts (B), connect each line coming out of the timer to the wires coming out from the in-wall junction

    box. Connect the black wire to the power-in wire and the red wire to the power-out wire.

  4. Insert timer into the wall box being careful not to pinch any wires. Be sure the Arrow (indicated on front of timer) is facing up.

    Fasten the timer to the wall box using the provided screws (C).

  5. Place provided wall plate and time dial plate on timer referring to the appropriate diagram above.

  6. Carefully screw on the provided nut.

  7. Push timer knob onto knob extension. Be sure the pointer is lined up with “OFF” on dial plate. 

  8. Use the provided screws (D) to secure the wall plate.

  9. Turn power on at the circuit breaker or fuse box. 

3. Set the countdown time

  1. Turn the knob switch clockwise until the slot of knob aligns with dial mark of cover plate. 

  2. Turn on the main power.
You may turn OFF the load at any time while it is ON by simply moving the knob switch counterclockwise to the OFF.

To turn the load ON again, just turn switch to the desired time.

The timer may be reset at any time by turning the load OFF and back the desired time.

OFF

Turn
Past

10

20

30

40

50

60

minutes

A

B

C

D

WB015 / WB030 / WB060

WB015/WB030/WB060

1. Assembly layout

STANDARD JUNCTION BOX

TIMER

KNOB

NUT

TIME DIAL PLATE

WALL PLATE

SCREW (D)

SCREW (C)