Section 1 - Safety & Warnings 

1.1 Safety Guidelines 

This manual contains information that is very important to know and understand. This information is provided for SAFETY and 
to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.

 

 

- Danger indicates an imminently hazardous situation which, if not avoided, WILL 
result in death or serious injury. 
 
 
- Warning indicates a potentially hazardous situation which, if not avoided COULD 
result in death or serious injury. 
 
 
- Caution indicates a potentially hazardous situation which, if not avoided, MAY 
result in minor or moderate injury. 
 
 
 
- Notice indicates important information, that if not followed may cause damage to 
equipment. 

 

1.2 General Information

 

This

  compressor  is  intended  for  installation  indoors  for  use  on  dry  sprinkler  systems  in  accordance  with  the  Standard  for 

Installation of Sprinkler Systems, NFPA 13 and the National Electrical Code, NFPA 70. The compressor should be sized to 
restore and maintain the air pressure in the sprinkler system in accordance with the requirements in NFPA 13. 

 

1.3 General Safety Information 

1. 

Read all manuals included with this product carefully. Be thoroughly familiar with the controls and the 
proper use of the  equipment.

 

2. 

Follow all local electrical and safety codes as well as National Electrical Codes (NEC), Occupational 
Safety and Health Act (OSHA), and National Fire Protection Association  (NFPA).

 

3. 

Only persons familiar with these rules of safe operation should be allowed to use the equipment.

 

4. 

Keep visitors away and NEVER allow children in the work  area.

 

5. 

Wear safety glasses and use hearing protection when operating the  unit.

 

6. 

Do not stand on or use the unit as a  handhold.

 

7. 

Periodic inspection and test of this equipment is required. 

Consult your installer and local codes 

to meet all requirements.

 

8. 

Check all fasteners at frequent intervals for proper  tightness.

 

 

1.4 Safety Notes 

 

This compressor is not equipped and should NOT be used “as is” to supply breathing 

quality air. 
 
 
-  Motors,  electrical  equipment  and  controls  can  cause  electrical  arcs  that  will  ignite 
flammable gas or vapor. Never operate or repair in or near flammable gas or vapor. Never 
store flammable liquids or gasses near the compressor. 
 
 
-  These  compressors  are  suitable  for  pumping  only  atmospheric  air.  As  defined  in 
Compressed  Gas  Association  Pamphlet  G-7,  page  3,  atmospheric  air  is  a  mixture  of 
elements and compounds where nitrogen and oxygen comprise more than 99% with all 
other  trace  gasses  comprising  less  than  1%. 

Do  not  use  this  compressor  in 

contaminated environments or for pumping mixtures other than atmospheric air

 

 

 

DANGER

 

WARNING

 

CAUTION
 

 

NOTICE

 

DANGER

 

WARNING

 

WARNING

 

Summary of Contents for QRM2 Series

Page 1: ...ank Mounted Quiet Oil less Air Compressors Installation Operation and Maintenance Manual For 60Hz Models Only Reliable Automatic Sprinkler Co Inc 103 Fairview Park Drive Elmsford New York 10523 800 55...

Page 2: ...Instruction QRM2 Mounting Bracket Section 5 Lubrication Section 6 Piping 6 1 Piping Instructions 6 2 QRM2 Series Riser Mounted Quiet Oilless Air Compressor Installation Drawing 6 3 QRM2 T Series Tank...

Page 3: ...ment 2 Follow all local electrical and safety codes as well as National Electrical Codes NEC Occupational Safety and Health Act OSHA and National Fire Protection Association NFPA 3 Only persons famili...

Page 4: ...an well ventilated area where air is relatively cool clean and dry A 104 F 40 C maximum and 40 F 4 C minimum temperature for surrounding and inlet air are recommended Provide at least 12 to 18 inches...

Page 5: ...n IMPORTANT NOTE Torque straps screws to 35 to 40 in lbs 4 3 Basic Instructions QRM2 Mounting Bracket 1 2 Use the rectangular holes on the bracket to rest it on the riser plate hooks A B C D Securely...

Page 6: ...re at the AMD is 200 F or less An AMD must be used with all riser mounted tank units All oilless compressors include a relief valve which is installed on the compressor This valve will open at a prese...

Page 7: ...6 Section 6 Piping 6 2 QRM2 Series Riser Mounted Oilless Air Compressor Installation Drawing...

Page 8: ...7 6 3 QRM2 T Series Tank Mounted Oilless Air Compressor Installation Drawing...

Page 9: ...ed on a 100 run and lowest operating voltage Consult factory for longer runs Single phase motors include internal thermal overload protection which has an automatic reset device Disconnect electrical...

Page 10: ...9 7 2 Oilless Air Compressor Single Phase Wiring Drawing...

Page 11: ...with Tank RASCO Part Number 6990021905 Factory Set at 50 PSIG Cut IN 70 PSIG Cut OUT QRM2 Models without Tank RASCO Part Number 6990021904 Factory Set at 20 PSIG Cut IN 26 PSIG Cut OUT Differential P...

Page 12: ...lower voltage drop 2 Replace compressor 3 Replace check valve 4 Repair or replace pressure switch Reset mechanism cuts out or fuses blow repeatedly 1 Insufficient voltage to motor 2 Pressure switch se...

Page 13: ...EXCEPT AS TO TITLE THE COMPANY MAKES NO OTHER WARRANTIES EXPRESSED OR IMPLIED OR STATUTORY INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY THE REMEDY PROVIDED UNDER THIS WARRANTY SHALL BE THE SOLE E...

Reviews: