background image

2.

Available Configurations, Listings, and Approvals

Sprinkler

Model

Escutcheon or

Cover Plate

Available Length

(See Figs. 1 - 7)

Listings and

Approvals

(1)

Inlet

Threads

Sprinkler Identification

 Number (SIN)

F3-80 Dry

Pendent

Standard

Escutcheon

2” to 36”

(50 to 914 mm)

cULus, NYC

1” NPT

or

ISO7-1R1

RA6012

HB Extended Escutcheon

3-1/2” to 36”

(90 to 914 mm)

FP Recessed Escutcheon

CCP Cover Plate

F3-80 Dry

Horizontal 

Sidewall

Standard Escutcheon

2” to 36”

(50 to 914 mm)

cULus

(2)

, NYC

(2)

1” NPT

or

ISO7-1R1

RA6032

HB Extended Escutcheon

3-1/2” to 36”

(90 to 914 mm)

FP Recessed Escutcheon

(1) 

For available temperature ratings and finishes see the Temperature Ratings and Finishes tables, respectively, in this Bulletin.

(2)

 cULus Listing and NYC for Light Hazard (existing) and Ordinary Hazard only.

Listing and Approval Agencies

See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to 
each available configuration.
1.  Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus)
2.  Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC)

Technical Data

Maximum Listed and Approved Working Pressure: 175 psi (12 bar)
Nominal K-Factor: 8.0 gpm/psi

1/2

 (115 L/min/bar

1/2

)

Temperature 

Classification

Glass Bulb Color

Sprinkler

Temperature Rating

Cover Plate

Temperature Rating

Maximum Ceiling 

Temperature

Listings and

Approvals

(1)

Ordinary

Orange

135°F (57°C)

135°F (57°C)

100°F (38°C)

cULus, NYC

Red

155°F (68°C)

Intermediate

Yellow

175°F (79°C)

165°F (74°C)

150°F (66°C)

Intermediate

Green

200°F (93°C)

165°F (74°C)

150°F (66°C)

High

Blue

286°F (141°C)

None

225°F (107°C)

165°F (74°C)

150°F (66°C)

(1)

 For listed and approved sprinkler, escutcheon, and inlet configurations see the Available Configurations, Listings, and Approvals table in this Bulletin.

Finishes

Component

Sprinkler

Escutcheon

(1)

Cover Plate

Standard Finishes

Bronze

Brass

(3)

White Paint

White Polyester

(2)

White Polyester

Chrome

Chrome

Chrome

Special Application Finishes

Electroless Nickel PTFE

(2)

Type 316 Stainless Steel

Satin Chrome

Black Paint

Custom Color Paint

Black Plating

Black Polyester

(2)

Black Polyester

Custom Color Polyester

Customer Color Polyester

Wax Coated

(4)

High Temp. Wax Coated

(5)

Lead Plated

(4)

Wax Over Lead

(4)

High Temp. Wax Over Lead

(5)

(1)

 Standard and Model HB escutcheons are supplied with both the can and escutcheon finished. Model FP escutcheons are supplied with the escutcheon 

finished; the cup is galvanized or stainless steel with no further finish.

(2)

 cULus Listed as a Corrosion Resistant Sprinkler.

(3)

 Brass finish available for standard Model FP escutcheons only.

(4)

 Wax coating, lead plating, and wax over lead finishes are Listed and available for 155°F (68°C), 175°F (79°C), and 200°F (93°C) activation temperature 

sprinklers only.

(5)

 High temperature wax coating and high temperature wax over lead finishes are Listed and available for 286°F (141°C) activation temperature sprinklers 

only and shall only be installed where maximum ceiling temperature does not exceed 150°F (66°C).

Summary of Contents for F3-80 Dry Horizontal Sidewall

Page 1: ...able in this Bulletin for available temperature rat ings Model F3 80 Dry sprinklers are intended for installa tion on wet pipe dry pipe or preaction sprinkler systems in accordance with NFPA 13 Model...

Page 2: ...range 135 F 57 C 135 F 57 C 100 F 38 C cULus NYC Red 155 F 68 C Intermediate Yellow 175 F 79 C 165 F 74 C 150 F 66 C Intermediate Green 200 F 93 C 165 F 74 C 150 F 66 C High Blue 286 F 141 C None 225...

Page 3: ...en escutcheon is in nominal position Escutcheon adjustment provides 6mm to 1 32mm A dimension adjustment range Fig 1 Model F3 80 Dry Pendent Sprinkler with Standard Escutcheon SIN RA6012 A Dim 2 to 36...

Page 4: ...HB Extended Escutcheon SIN RA6012 A Dim 3 to 36 89mm to 914mm in 1 4 6mm increments Note The sprinkler can protrudes 1 when escutcheon is in nominal position Escutcheon adjustment provides 12 7mm to...

Page 5: ...dent sprinkler with the Model FP escutcheon in ceilings which have positive pressure in the space above Fig 3 5 Model F3 80 Dry Pendent Sprinkler with Model FP Recessed Escutcheon SIN RA6012 A Dim 31...

Page 6: ...del CCP Cover Plate SIN RA6012 A Dim 31 2 to 36 89mm to 914mm in 1 4 6mm increments Note Do not install the Model F3 80 Dry Pendent sprinkler with the Model CCP cover plate in ceilings which have posi...

Page 7: ...ustment provides 6mm to 1 32mm A dimension adjustment range Fig 5 7 Model F3 80 Dry Horizontal Sidewall Sprinkler with Standard Escutcheon SIN RA6032 A Dim 2 to 48 51mm to 1219mm in 1 4 6mm increments...

Page 8: ...31 2 to 48 89mm to 1219mm in 1 4 6mm increments for 1 connections or 3 to 36 89mm to 914mm in 1 4 6mm increments for 3 4 connections Note The sprinkler can protrudes 1 when escutcheon is in nominal po...

Page 9: ...48 89mm to 1219mm in 1 4 6mm increments for 1 connections or 3 to 36 89mm to 914mm in 1 4 6mm increments for 3 4 connections Note Do not install the Model F3 80 Dry Horizontal Sidewall sprinkler with...

Page 10: ...10 Fig 8...

Page 11: ...Fig 9 11...

Page 12: ...Fig 11 Model XLO2 Wrench Fig 10 Model F3R Wrench 12...

Page 13: ...Fig 12 13...

Page 14: ...he es cutcheon or cover plate option selected 2 Apply pipe joint compound or PTFE tape to the male threads of the sprinkler s inlet fitting 3 Install the sprinkler in the fitting using the installatio...

Page 15: ...een the bulb supporting cup and the wrenching boss Do not replace this wax with a substitute substance An Alternate substance may interfere with proper operation of the sprinkler Do not clean sprinkle...

Reviews: