Selection of Application Fittings (Mist Reclassifiers) 

Included with the LubriMate

®

  Unit are three sizes of application fittings (mist reclassifiers).  A quantity of five for each type of 

application fittings is provided to suit a range of oil mist flow requirements: 
 

  77-800-501; Mist Reclassifer, Rated 0.09 SCFM @ 20 In H

2

  77-800-502; Mist Reclassifer, Rated 0.18 SCFM @ 20 In H

2

  77-800-503; Mist Reclassifer, Rated 0.30 SCFM @ 20 In H

2

Pure Mist

 

For oil mist lubrication of anti-friction/rolling element bearings under normal operating conditions, two factors are to be considered:  
the shaft diameter at the bearing and the number of rows of bearings.  The table below should be followed to select the correct 
size reclassifier. 
 

Pure Mist:  Anti-Friction/Rolling Element Bearings

 

Shaft Diameter @ Bearing 

Single Row Bearing 

Double Row or Duplex Bearing 

< 1.77 in. (45 mm) 

77-800-501 

77-800-502 

1.77 in. (45 mm) 

to 

2.95 in. (75 mm) 

77-800-502 

77-800-503 

>2.95 in. (75 mm) 

to 

5.51 in. (140 mm) 

77-800-503 

Use Purge Application or Consult 

Your manufacturer Representative 

 

 
 

Purge Mist 

With purge mist, the lubrication of the machine elements is maintained by the splash or recirculation of the oil from the oil 
reservoir.  The purge mist itself does not provide the lubrication rather it fills and flows through the volume space above the oil 
level.  Therefore, achieving adequate flow through that volume is important and should be considered when selecting reclassifiers 
for purge mist applications.  The sizing requirement is established by knowing the approximate volume space above the oil level.  
The following table provides guidelines for selecting the correct reclassifier for purge mist applications. 

 

Purge Mist:  Sleeve Bearings and Gear Boxes 

Internal Volume 

(Volume Space 

Above The Oil Level) 

Less Than 2 Cubic Feet 

(56 Liters) 

2 Cubic Feet 

(56 Liters) or More 

Mist Reclassifier 

77-800-501 

77-800-502 

 

IMPORTANT

 

The last three digits of the part number are stamped on the mist reclassifier.  Inspect the mist 
reclassifier to insure that the correct part is being installed. 

IMPORTANT 

1. Mist reclassifiers are to be mounted on the equipment receiving the oil mist and not 

on the LubriMate

®

 except when additional flow is required as described below. 

2. If the equipment to be operated or tested will  rotate at speed greater than 3600 

RPM or will be tested or operated under conditions that place extreme thrust 
loading on the bearings, consult your manufacturer representative. 

 

 

 

 

 

Summary of Contents for LUBRIMATE

Page 1: ...NO SERIAL NO LubriMist MIST PRESSURE SWITCH RATING OIL HEATER VOLTS WATTS P O BOX 19294 HOUSTON TEXAS 77224 9294 713 464 6266 FAX 713 464 9871 1 800 800 LUBE www lsc com THE RIGHT CHOICE Lubrication...

Page 2: ...gn with coalescing filter eliminates stray mist from venting at the unit thus test stands remain clean and free of oil mist This publication provides instruction and information on the set up and oper...

Page 3: ...into the bearing housing A drain tube connects the bearing housing drain to any of five return ports located on the LubriMate The air stripper separates the remaining oil from the returned oil mist T...

Page 4: ...to the inlet air pressure regulator filter 1 8 NPT located at the left side of the unit The inlet air supply should be capable of delivering 4 SCFM at 55 PSIG This is the minimum required air pressure...

Page 5: ...ation For gear boxes and sleeve bearings with oil level the purge oil mist method is to be used With purge mist the air space above the oil level is filled with oil mist The resulting purge keeps outs...

Page 6: ...ents is maintained by the splash or recirculation of the oil from the oil reservoir The purge mist itself does not provide the lubrication rather it fills and flows through the volume space above the...

Page 7: ...istent Viscosity Grade Minimum Operating Temperature ISO 32 32 F 0 C ISO 46 40 F 4 4 C ISO 68 50 F 9 9 C ISO 100 60 F 15 6 C ISO 150 70 F 21 0 C ISO 150 Not Recommended Maintaining Minimum Air Flow to...

Page 8: ...over time the stripping filter element becomes saturated with oil This is normal and expected However the resulting increased pressure drop across the filter may cause a portion of the returning mist...

Page 9: ...a leak or loose connection in the supply tubing a missing application fitting or a broken line 5 2 High mist pressure may indicate plugged application fitting or a restricted bearing housing vent or d...

Page 10: ...CH RATING OIL HEATER VOLTS WATTS P O BOX 19294 HOUSTON TEXAS 77224 9294 713 464 6266 FAX 713 464 9871 1 800 800 LUBE www lsc com THE RIGHT CHOICE Lubrication Systems Company FULL ADD OIL LEVEL 131 2 1...

Page 11: ...ches of H2O 2 77 700 744 Return Pressure Gauge 3 77 700 743 Air Stripping Coalescing Filter Element 4 77 700 742 Bulls Eye Sight Glass 5 LS 02 05 120 Oil Suction Screen 6 77 600 807 Air Filter Pressur...