REKA III

 

As soon as the gun has warmed up, open cover (no. 13) by turning the star grip (no. 14) to the left.  

Before loading the cartridge (310 ml), mount enclosed adapter incl. nozzle, making sure that the 
cartridge has been opened.

 

To close the cover turn grip to the right. 

Allow approx. 3 - 10 minutes, depending on quantity and type of glue, for the gun to melt the glue.The 
quantity to be applied can be determined by pressing the trigger (no. 27); the longer you press, the more 
glue comes out. 

 
 

Application of Hot Melts 
 

Make yourself familiar with the instrument first. Apply a little glue in varying forms (small, large dots) on a 
piece of paper or cardboard. This is very easy. Try to find out the correct quantity and the ideal pattern by 
adjusting the pressure controllers at the stand to different pressures. 
Observe the correct working temperatures of the individual hot melt. 

Never start working without having mounted a nozzle! 
 
 
Nozzle Replacement 

 
Only replace nozzles when the glue gun is warm (instrument temperature 60 - 80°C / approx. 140 - 170 °F) 
and empty. For the replacement you need a SW 13 open-end spanner. You are advised to wear gloves. 

 

 

Prior to exchanging nozzles, unplug connecting cable! 
 

Replacing a cold nozzle may damage the gun. If the nozzle is replaced when it is too hot, liquid adhesive 
may leak out. 

 

 

 

Warning: Risk of burning! 
 

When your skin got into contact with hot glue, immediately cool it with cold water. 

Do not try to remove hot melt from the skin first. If necessary consult your doctor. 

When hot adhesive got in your eyes, immediately cool them under running water for about 15 minutes. 

Consult your doctor at once! 

 

 

 
Never start working without having mounted a nozzle! 
Do not direct glue jet towards people! 
 
 
Working with Stationary Equipment 

(in connection with pneumatic foot switch) 
 
To work with stationary equipment mount glue gun and foot switch according to enclosed drawings 
„Connection of Foot Switch“ and „Stationary Equipment“. Then, proceed as follows: 

-

 

Press trigger (no.27) down to stop and hold it 

-

 

Plug enclosed screw into the borehole provided for this purpose at one side of the casing handle 

-

 

Let trigger loose 

-

 

Trigger is locked  

Art. Nr. 9106           

                                                                                                                        8

 

 

 

Summary of Contents for TR 70 LCD Series

Page 1: ...REKA III Art Nr 9106 Operating Instructions for Reka Hot Melt Glue Gun TR 70 LCD Cartridge Glue Gun...

Page 2: ...of Contents Product Description 3 Trouble Shooting 4 General Safety Instructions 5 Start up 7 Operation 9 Additional Information 10 EC Conformity Certificate 11 Exploded Views 12 Spare Parts Legend I...

Page 3: ...not be the manufacturer s but the user s responsibility Technical Data Connection 230 V 110 V Heating capacity 400 W Air control glue 0 15 7 bars Air consumption max 100 l min Temperature control elec...

Page 4: ...le clean or replace it check controller check temperature replace valve Glue is too fluid or too con sistent temperature too high or too low check temperature Glue leaks out of nozzle sound absorber g...

Page 5: ...erating instructions and in particular the safety instructions Make the information available This operating manual shall be kept on the site of operation It must be ensured that all persons operating...

Page 6: ...isk of burning Never bring the hot nozzle into contact with the cable When your skin got into contact with hot glue immediately cool it with cold water Do not try to remove hot melt from the skin firs...

Page 7: ...ng the key 3 the device will use the last chosen temperature While the device is heating up to the chosen temperature the numbers on the display are blinking Minor leaking during heat up phase is due...

Page 8: ...n is warm instrument temperature 60 80 C approx 140 170 F and empty For the replacement you need a SW 13 open end spanner You are advised to wear gloves Prior to exchanging nozzles unplug connecting c...

Page 9: ...nd unless it is fitted to a balancer Never lay gun on its side Open premelting tank only if required Keep hot melt free of dirt and humidity When using the stand remove wire strap General Hints Should...

Page 10: ...tank Contaminated glue nails clamps sand etc cause malfunctions If you observe the operating instructions the gun does normally not need cleaning When PUR hot melts are used the adapter and nozzles ha...

Page 11: ...ndards have been applied EN 60335 EN 292 EN 60204 HD 400 EN 55014 EN 60555 EN 61000 Design modifications influencing the technical data specified in the operating manual and the in tended use thus mea...

Page 12: ...REKA III Art Nr 9106 12...

Page 13: ...rber 7 2693 DT SEV D 16 8 2694 Cap SEV D 18 9 2696 Membrane SEV 10 2697 90 fitting SEV 11 2955 Flat seal 12 2953 Cartridge opener 13 2959 Lid without SEV 14 2613 Star grip 15 3665 Lock nut 16 2883 Lid...

Page 14: ...REKA III Art Nr 9106 14...

Reviews: