background image

 

                                                                                            

 

 

REKA III

 

 
To avoid risk of stumbling: 

Lay all instrument connections (cables, hoses, and lines) so that they do not cause any risk of stumbling 
(cable conduits, bridges)! 
 

Make supply connections and settings 

 

Connect the TR 70 LCD Glue Gun to the electric mains of 230 V / 110 V and a compressed air line of max. 6 
bars. 

Plug connecting cable into socket with earthing contact. 

Adjust working temperature for hot melt. 

 

 

 

 

 
1 = raise temperature  2 = lower temperature  3 = on / off / confirmation 

Switch on: 

 

Press the 

key 3

 to switch the glue gun on. 

Raise temperature: 

Press  the 

key 1

 until the desired temperature is displayed. For confirmation press 

one time

 the 

key 3

Lower temperature: 

Press  the 

key 2

 until the desired temperature is displayed. For confirmation press 

one time

 the 

key 3

If the chosen temperature is not confirmed within a few seconds by pressing the key 3, the device will use 
the last chosen temperature. While the device is heating up to the chosen temperature, the numbers on the 
display are blinking. 

Minor leaking during heat-up phase is due to hot melt expanding in the nozzle/heating chamber. 
As soon as the working temperature is reached, the hot melt will not leak out anymore. 

 

Attention:  Temperature regulation not calibrated! 
 

If an exact temperature is needed, it must be 

 

checked with a suitable temperature sensing tool.

 

Checkpoint

 

Attention:  After heating up, nozzle and cap are extremely hot! 

 

Never work without hand gloves. 

 
Stand incl. pressure controller and manometer 
 
When the stand is used as a deposit, do not fit the wire strap to the gun! 

 
Precise adjustment of compressed air ensures an exact regulation of the glue quantity to be applied. The 
adjusted pressure may be read from the manometer indication. 
 

Mount compressed air hose between glue gun and stand 

Connect compressed air hose for main connection to the rear side of the stand. 

 

 
 

Loading of Glue Cartridge

 

 

Art. Nr. 9106           

                                                                                                                        7

 

 

 

Summary of Contents for TR 70 LCD Series

Page 1: ...REKA III Art Nr 9106 Operating Instructions for Reka Hot Melt Glue Gun TR 70 LCD Cartridge Glue Gun...

Page 2: ...of Contents Product Description 3 Trouble Shooting 4 General Safety Instructions 5 Start up 7 Operation 9 Additional Information 10 EC Conformity Certificate 11 Exploded Views 12 Spare Parts Legend I...

Page 3: ...not be the manufacturer s but the user s responsibility Technical Data Connection 230 V 110 V Heating capacity 400 W Air control glue 0 15 7 bars Air consumption max 100 l min Temperature control elec...

Page 4: ...le clean or replace it check controller check temperature replace valve Glue is too fluid or too con sistent temperature too high or too low check temperature Glue leaks out of nozzle sound absorber g...

Page 5: ...erating instructions and in particular the safety instructions Make the information available This operating manual shall be kept on the site of operation It must be ensured that all persons operating...

Page 6: ...isk of burning Never bring the hot nozzle into contact with the cable When your skin got into contact with hot glue immediately cool it with cold water Do not try to remove hot melt from the skin firs...

Page 7: ...ng the key 3 the device will use the last chosen temperature While the device is heating up to the chosen temperature the numbers on the display are blinking Minor leaking during heat up phase is due...

Page 8: ...n is warm instrument temperature 60 80 C approx 140 170 F and empty For the replacement you need a SW 13 open end spanner You are advised to wear gloves Prior to exchanging nozzles unplug connecting c...

Page 9: ...nd unless it is fitted to a balancer Never lay gun on its side Open premelting tank only if required Keep hot melt free of dirt and humidity When using the stand remove wire strap General Hints Should...

Page 10: ...tank Contaminated glue nails clamps sand etc cause malfunctions If you observe the operating instructions the gun does normally not need cleaning When PUR hot melts are used the adapter and nozzles ha...

Page 11: ...ndards have been applied EN 60335 EN 292 EN 60204 HD 400 EN 55014 EN 60555 EN 61000 Design modifications influencing the technical data specified in the operating manual and the in tended use thus mea...

Page 12: ...REKA III Art Nr 9106 12...

Page 13: ...rber 7 2693 DT SEV D 16 8 2694 Cap SEV D 18 9 2696 Membrane SEV 10 2697 90 fitting SEV 11 2955 Flat seal 12 2953 Cartridge opener 13 2959 Lid without SEV 14 2613 Star grip 15 3665 Lock nut 16 2883 Lid...

Page 14: ...REKA III Art Nr 9106 14...

Reviews: