S-AGR08gb08
05/15 - 3
Page 3 of 15
8 Maintenance
4. Sliding head holder (11) backwards from the
spray head (8). Remove paint needle (13),
small compression spring (16), big compres
-
sion ring (15) and spring pin (14).
Remove two Viton O-rings (10) from the spray
head holder for fan air and atomizing air.
Attention: Risk of injury!
Needle can be very sharp.