background image

Regulations, Standards & Directives

This product complies with the following:

    

ATEX Directive - 2014/34/EU

    

Machinery Directive 2006/42/EC 

    

PPE Regulation (EU) 2016/425

    

The Provision and Use of Work Equipment 
Regulations 1998 (S.I. 1998 No. 2306)

    

The Lifting Operations and Lifting Equipment 
Regulations 1998 (S.I. 1998 No. 2307)

    

In conformity with EN795:2012, AS/NZS 
5532:2013 and PD CEN/TS 16415:2013 

It is essential to adhere to the safety regulations 
of the respective country for using manual lifting 
equipment. 

Accreditations

Quality and Safety are at the heart of the REID 
Lifting ethos and we are committed to maintaining 
the very highest standards. With this in mind, we 
have undertaken external accreditations to ensure 
we stay focused on what is important to our 
clients and users, and ahead of market trends and 
developments. 

REID Lifting is continuously audited by Lloyds 
Register Quality Assurance (LRQA) for approval 
of its Integrated Management System combining 
quality systems management, environmental 
issues and the health and safety practices within 
the company. 

    

ISO 9001:2015 - Quality management 
system which assesses an organization’s 
ability to consistently provide products that 
meet customer and applicable regulatory 
requirements and aims to enhance customer 
satisfaction. 

    

ISO 14001:2015 - Specifies the requirements 
for implementing environmental management 
systems throughout all areas of the organization. 

    

OHSAS 18001:2007 - Occupational health and 
safety management system. 

    

LEEA Membership - REID Lifting is a full member 
of the Lifting Equipment Engineers Association 
(LEEA membership 000897). REID Lifting 
conforms to the main aims of the association 
which is to achieve the highest standards 
of quality and integrity in the operations of 
members. Entry qualifications are demanding 
and strictly enforced through technical audits 
based on the Technical Requirements for 
Members. 

    

IRATA - REID Lifting is an associate member of 
the Industrial Rope Access Trade Association 
(IRATA International membership number 148). 
REID Lifting works in accordance with the IRATA 
Code of Practice and, in doing so, contributes to 
promote the development of safe systems. 

Quality & Safety

Summary of Contents for T DAVIT

Page 1: ...US REIDLIFTING COM Assembly Operation Guide TDAVIT...

Page 2: ...ections Maintenance Repair Storage Transportation Sockets Socket Installation Minimum Mounting Requirements Verifying the Installation ATEX 12 ATEX Classification Zone 2 Classification Zone 1 Spark Fo...

Page 3: ...apply for Operation including preparation troubleshooting during operation and cleaning Maintenance inspection and repair Transportation It is the responsibility of the end user to adhere to the Healt...

Page 4: ...city indicated on the product Personnel Lifting When lifting people the overall load limit is reduced by half to provide an increased safety factor The maximum capacity permitted by the personnel winc...

Page 5: ...ecommend that gloves are worn when using the equipment Attach the hoist to the dedicated lifting point only making sure it is attached in a way that does not expose the user to danger by the hoist cha...

Page 6: ...uch as trapping fingers in rotating parts Be aware of any adverse weather conditions such as strong or gusty winds which could impose additional horizontal loads and affect the stability of the struct...

Page 7: ...on climatic exposure on the fall protection lifelines and the effect of offset forces as a result of pendulum falls Where regulations require each installation must be approved by a qualified person W...

Page 8: ...sh with the top of the socket Regular Inspections To ensure that the product s remains in safe working order it must be inspected regularly by a competent person We recommend inspections every 6 month...

Page 9: ...equipment in a clean and dry manner Cleaning is suggested using a sponge or cloth with warm soapy water rinsing and allowing to dry This product must be assembled using metric fixings of the same typ...

Page 10: ...into new concrete or resin bonded into existing concrete Socket Installation Socket installation should only be carried out by a qualified person with the ability to specify the anchors resin and fas...

Page 11: ...n verifying the installation testing should be to no more than 125 of the goods capacity at its maximum reach All tests should be carried out in all anticipated worst case loading directions sustained...

Page 12: ...ures are unlikely to occur or if they do occur are likely to do so only infrequently and for a short period only The product will have the following identification on the serial label As Standard for...

Page 13: ...hing cable should be used Inspection Maintenance Repair Special attention should be given to dust deposits on the structure especially in areas where the profiles come into contact and should be wiped...

Page 14: ...Top Mount Side Mount Bridge Mount Cast In or Resin Bonded depending on application The T DAVIT shown is a winched version but an unwinched variant is also available Appropriate PPE should be worn Glo...

Page 15: ...p Present the beam to the chosen location and insert the clevis pin The T DAVIT beam can be assembled at 2 positions as shown Ensure the correct set up is chosen at this stage 15 TDAVIT Assembling the...

Page 16: ...ert the clevis pin to take the weight of the beam Secure the pin with the R clip For disassembly reverse steps 1 9 In some circumstances the winch can be used to rotate the beam in line for the pin in...

Page 17: ...17 TDAVIT Variants Options Type VW...

Page 18: ...ay vary between a Top Mount Side Mount Bridge Mount Cast In or Resin Bonded depending on application Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly Instructions Socket Top...

Page 19: ...vent the beam from disengaging Place the winch and bracket in position Place winch attachment column to the beam as shown Secure attachment with the nuts and bolts supplied 19 TDAVIT Assembling the T...

Page 20: ...lied Thread the rope over the sheaves The rope retaining pins need to be removed before fitting the rope Reinsert pins ensuring they are secure Please refer to the Operating manual of the winch before...

Page 21: ...21 TDAVIT Variants Options Type T...

Page 22: ...extension is optional and the socket type may vary between a Top Mount Side Mount Bridge Mount Cast In or Resin Bonded depending on application Appropriate PPE should be worn Gloves Protective Footwe...

Page 23: ...Reinsert bolt and spacer ensuring they are secure Insert T Davit column into the socket Thread beam trolley over the end of the beam Lock trolley with friction brake at approximately centre position 2...

Page 24: ...e pin with retaining R clip The T Davit is now erect Rotate the beam as illustrated Insert rear clevis pin Present the beam to the column and insert clevis pin to take the weight of the beam Assembly...

Page 25: ...Release trolley brake Use the hand chain to move the trolley along the beam 25 TDAVIT 12 13...

Page 26: ...Variants Options...

Page 27: ...e configuration users can experience a maximum effort of 78lb The rotation should be done in a controlled manner When the rotational handle is attached to the Davit the following points must be observ...

Page 28: ...n A Height of Lift Position B Winch Position 1 Winch Position 2 Winch Position 3 Winch Position 4 Winch Position 5 Height of Pin Position 1 Height of Pin Position 2 A W1 W2 W3 W4 P1 W5 P2 B C D TDAVIT...

Page 29: ...D C D Weight lbs Winch Position P1 P2 3 52 64 52 67 N A N A 51 W1 7 58 61 W2 12 W3 24 W4 29 W5 34 4 N A N A 64 80 64 86 55 W3 24 70 74 W4 29 W5 34 Beam Option 1 2 3 BEAM LENGTH 57 65 80 DIMENSION A B...

Page 30: ...ions Radius Position A Radius Position B Height of Lift Position A Height of Lift Position B Height of Pin Position 1 Height of Pin Position 2 A P1 P2 B C D TDAVIT D C B A P1 P2 Type S Position A Posi...

Page 31: ...7 N A N A 51 W1 7 58 61 W2 12 W3 24 W4 29 W5 34 4 N A N A 64 80 64 86 55 W3 24 70 74 W4 29 W5 34 Beam Option 1 2 3 BEAM LENGTH 57 65 80 DIMENSION A B A B A B REACH 33 30 41 37 57 52 LOAD RATING lbs 11...

Page 32: ...nt environmental issues and the health and safety practices within the company ISO 9001 2015 Quality management system which assesses an organization s ability to consistently provide products that me...

Page 33: ...ile review are integral parts of our design and manufacturing process External verification of products is undertaken where appropriate using government approved Notified Bodies All products have been...

Page 34: ...Product Labelling Product labelling The following labels must be present on the product and must be legible lbs 1 2 3 4 6 3 3 4 6 5 1 2 5 2 1...

Page 35: ...rial number The goods capacity WLL of the device The year of manufacture The standards to which the device is approved The ATEX rating of the product if applicable CE Marking Minimum braking load MBL...

Page 36: ...com Printed using environment friendly processes and materials All information herein is copyright protected by REID Lifting Ltd All company and product names are Trade Mark and Trade Name protected a...

Reviews: