Putting the coupling into operation
49
Putting the coupling into operation
DANGER
Risk of explosion when operating the coupling in potentially
explosive atmospheres.
Risk of explosion with fatal injuries.
Exclusively use couplings bearing the corresponding ATEX
marking in potentially explosive atmospheres.
In this respect, read and follow the additional notes in the
supplementary manual for ATEX operation.
WARNING
Danger to life due to rupturing of a damaged coupling.
Exclusively operate the coupling in flawless condition.
Make sure that the coupling is equipped with a protection
device which is capable of withstanding rupturing of the
coupling.
Wear the personal protective equipment specified by the owner.
Perform the following work prior to commissioning:
Make sure that all bolted connections are tightened to the required torque.
Check the alignment of the coupling.
Correct the alignment if necessary.
Make sure that a protection device is mounted and functional.
Proceed as follows to commission the coupling:
Start the drive unit as specified by the owner.
Check the coupling for low-noise and vibration-free running.
If this is not the case, shut the drive unit off as specified by the owner.
Search for the cause of the malfunction.
Eliminate the malfunction.
Repeat commissioning.