Installationsschema 2x Base und 2 x R-Modul / Wiring diagram 2x Base with 2x R-Module / Schéma d’installation 2 stations de base et 2 modules R / Installationsschema 2x Base och 2 x R-modul / 

Installatieschema 2x Base en 2 x R-module / Schema d‘installazione 2x base e 2 x modulo R / Esquema de instalación 2 bases y 2 módulos R / Schéma instalace 2x Base s 2x modul R / Szerelési vázlat 

2x Base és 2 x R-modul / Schema de instalare 2x Base cu 2 x modul R / 2 x Base ve 2 x R modüllü kurulum şeması / Schemat instalacji 2 x Base i 2 x moduł R / Монтажная схема 2 баз и 2 R-модулей:

ZOBUS1ZOBUS2

RELAY1 RELAY2 1 2 1 2 1 2 1 2

DI1

RZ9 RZ10 RZ11 RZ12 L1 L2

Transformator

ZOBUS1ZOBUS2

RELAY1 RELAY2 1 2 1 2 1 2 1 2

DI1

RZ9 RZ10 RZ11 RZ12 L1 L2

Transformator

L1

IN 24V ~ OUT 24V ~

L2

L1´

L2´

RELAY 1

RELAY 4

RELAY 2

RELAY 3

DI 1

RZ1

RZ2

RZ3

RZ4

RZ5

RZ6

RZ7

RZ8

DI 2

DI 3

DI 4

ZOBUS 2

ZOBUS 1

GND

1

2

VDC

SYSBUS

GND

1

2

VDC

SYSBUS

Transformator

L1

IN 24V ~ OUT 24V ~

L2

L1´

L2´

RELAY 1

RELAY 4

RELAY 2

RELAY 3

DI 1

RZ1

RZ2

RZ3

RZ4

RZ5

RZ6

RZ7

RZ8

DI 2

DI 3

DI 4

ZOBUS 2

ZOBUS 1

GND

1

2

VDC

SYSBUS

GND

1

2

VDC

SYSBUS

Transformator

ROOM UNIT
Display T RC

ROOM UNIT
Display T RC

ROOM UNIT
Display T RC

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

J-(Y) ST Y 2 x 2 x 0.8 mm /
existing 2-core wire

J-(Y) ST Y 2 x 2 x 0.8 mm /
existing 2-core wire

Base - Master

230 V AC

24 V AC

ETHERNET

WIFI-Router

Max. 12 Actuators UNI

ROOM UNIT
Display T RC

ROOM UNIT
Display T RC

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

ROOM UNIT
Display T RC

ROOM UNIT
Display T RC

ROOM UNIT
Display T RC

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

Base - Slave

230 V AC

24 V AC

ETHERNET

Max. 12 Actuators UNI

ROOM UNIT
Display T RC

ROOM UNIT
Display T RC

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

230 V AC

24 V AC

R-Module

230 V AC

24 V AC

R-Module

ETHERNET 
CABLE RJ-45

WIFI

IJ-(Y) ST Y 2 x 2 x 0.8 mm

max. 8 room units RC or Bus 
on each Base,  
max. 4 room units RC or Bus 
on each R­Module.

Installationsschema Base mit R-Modul und U-Modul / Wiring diagram Base with R-Module and U-Module / Schéma d’installation Station de base avec modules R et U / Installationsschema Base med 

R-modul och U-modul / Installatieschema Base met R-module en U-module / Schema d‘installazione base con modulo R e modulo U / Esquema de instalación base con módulo R y módulo U / Schéma 

instalace Base s modulem R a modulem U / Base szerelési vázlat R-modullal és U-modullal / Schema de instalare Base cu modul R și modul U / R modül ve U modüllü Base kurulum şeması / Schemat 

instalacji Base z modułem R i modułem U / Монтажная схема базы с R-модулем и U-модулем:

AI1

AI2

AI3

AI4

|  0/10V

DI1

DI1

GND 1

2 VDC

MODULE

ADDRESS

|

RELAY 1 RELAY 2 RELAY 3 RELAY 4

DI3

L2

L1

DI4

GND 1

2 VDC

ZOBUS1ZOBUS2

RELAY1 RELAY2 1 2 1 2 1 2 1 2

DI1

RZ9 RZ10 RZ11 RZ12 L1 L2

Transformator

L1

IN 24V ~ OUT 24V ~

L2

L1´

L2´

RELAY 1

RELAY 4

RELAY 2

RELAY 3

DI 1

RZ1

RZ2

RZ3

RZ4

RZ5

RZ6

RZ7

RZ8

DI 2

DI 3

DI 4

ZOBUS 2

ZOBUS 1

GND

1

2

VDC

SYSBUS

GND

1

2

VDC

SYSBUS

Transformator

ROOM UNIT
Display T RC

ROOM UNIT
Display T RC

ROOM UNIT
Display T RC

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

J-(Y) ST Y 2 x 2 x 0.8 mm /
existing 2-core wire

230 V AC

24 V AC

ETHERNET

WIFI-Router

Max. 12 Actuators UNI

ROOM UNIT
Display T RC

ROOM UNIT
Display T RC

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

ROOM UNIT
Display T Bus

230 V AC

24 V AC

PWR

0-10V

GND

M

3-way Valve

Flow

Temperature

Sensor

Return
Temperature
Sensor

U-Module - mixed circuit

R-Module

Base

ETHERNET 
CABLE RJ-45

WIFI

J-(Y) ST Y 2 x 2 x 0.8 mm

Max. 8 room units RC or Bus 
on each Base, 
max. 4 room units RC or Bus 
on each R­Module
U­Module defined as mixed 
circuit

Complex installation: startup possible only with WIZARD

Complex installation: startup possible only with WIZARD

Summary of Contents for NEA SMART 2.0 BASE 24 V

Page 1: ...a di iniziare l installazione Il col legamento alla rete elettrica finale deve essere effettuata solo dopo il completamento dell installazione Il fabbricante REHAU AG Co dichiara che il tipo di appare...

Page 2: ...re pe perete Duvara kurulum Instalacja na cianie b a c a 1 2 3 4 5 Installation auf der Hutschiene DIN Rail Installation Installation sur un profil chapeau Installation p DIN skena Installatie op prof...

Page 3: ...ule en extra regelbalken slaves SYSBUS per modulo U e basi aggiuntive slave SYSBUS para m dulo U y bases adicionales esclavos SYSBUS pro modul U a dopl kov rozvad e Slaves SYSBUS U modulhoz s kieg sz...

Page 4: ...per i primi 10 minuti Arrestare premendo OK sulla base per 3 sec Funci n First Open Todos los actuadores permanecen abiertos durante los primeros 10 minutos Presionar 3 segundos en la tecla OK de la b...

Page 5: ...R initialisation des param tres de la base la configuration d usine terst ll basen till fabriksinst llningarna Regelbalk naar fabrieksinstelling resetten Reset della base sull impostazione di fabbric...

Page 6: ...necessary ZOBUS1ZOBUS2 RELAY1 RELAY2 1 2 1 2 1 2 1 2 DI1 RZ9 RZ10 RZ11 RZ12 L1 L2 L1 IN 24V OUT 24V L2 L1 L2 RELAY 1 RELAY 4 RELAY 2 RELAY 3 DI 1 RZ1 RZ2 RZ3 RZ4 RZ5 RZ6 RZ7 RZ8 DI 2 DI 3 DI 4 ZOBUS 2...

Page 7: ...OM UNIT Display T Bus ROOM UNIT Display T Bus 230 V AC 24 V AC R Module 230 V AC 24 V AC R Module ETHERNET CABLE RJ 45 WIFI IJ Y ST Y 2 x 2 x 0 8 mm max 8 room units RC or Bus on each Base max 4 room...

Page 8: ...de traitement des donn es sont r serv s SE Dokumentet r upphovsr ttsskyddat D rigenom uppkomna r ttigheter f rbeh lles i synnerhet vad g ller vers ttning eftertryck kopiering radiering tergivning p f...

Reviews: