RehabPro MMS1 User Manual Download Page 5

 

1.

 

Disassemble the wire tightener by removing the plate and the 2x 8mm nuts. Place the lat wire in 
the tightener as shown in photo # 2 below (as close to the overhang as possible). 

Make sure the 

wire adjustment glider is at its lowest position on the number pole when you position the 
wire tightener.  

 
 

 
 
 
 
 
 
 
 
 
 
 
 

2.

 

Apply the thimble just below the tightener and bring the lat wire around it as shown in photo # 3 
above. Wind the wire around the two bolts as a figure eight. This will ensure the wire stays secure 
after the nuts are tightened.  

3.

 

Place the cover plate over the two bolts and secure the nuts (8mm) on the two bolts as shown in 
photo # 4 above.  

Note: Tighten the nuts on the bolts as hard as you can to ensure a secure fit. The plate on top 
of the wire should bend in the middle when the nuts are tightened all the way.  

4.

 

Place supplied heat shrink over the wire tightener assembly and shrink it by using a heat 
gun or a hair dryer. A finished assembly should resemble photo # 5 below.  

 
 
 
 

 
 

 
 
 

                                                     
                                               
 
 
 

 

 

 

 

 
 
At this point the module should be fully operational. Please contact RehabPro, Inc. with 
any issue you have either by calling 602-317-7207 or e-mail Kris van Scheers at 

[email protected]

 

                                                                                 