background image

1 - Description

VEGA 390 Thermal Store is intended for accumulation and subsequent distribution of heating wa-
ter thermal energy. It is 

fi

tted with a stainless steel immersed DHW heat exchanger, a 

fl

ange in the 

lower section permitting installation of a solar heat exchanger, enabling to install electric heating 
rods and to connect other heat sources (a heat pump or gas boiler). The Thermal Store shall be 
always connected to a sealed heating circuit.  
In order to reach proper working of the tank, it is necessary to design optimum hydraulics of the 
whole system, i.e. position of circulation pumps for sources and heating circuits, valves, non-return 
valves etc. When more heat sources shall be combined, it is recommended to use an intelligent 
controller, e.g. Regulus IR12, for both the source and load sides of a heating circuit, i.e. also for 
charging and discharging the Thermal Store.

1.1 - Models

VEGA 390 with stainless steel DHW heat exchanger.  

1.2 - Tank protection

The Thermal Store comes with no inner surface 

fi

nish, its outside painted in grey. Its DHW heat 

exchanger is made of stainless steel.

1.3 - Thermal insulation

Thermal insulation is included in the supply. It consists of 3 layers: the 

fi

rst one is soft insulation 

fi

tting tightly on the tank; the second, main layer, features thermal conductivity l=0.032 W/m.K; the 

third layer is a hard, glossy washable surface. The total insulation thickness is 100 mm.

1.4 - Connection points

1 top sleeve with G 1/2“ F thread
7 side sleeves with G 1/2“ F thread
2 side sleeves with G 6/4“ thread
6 side sleeves with G 1“ thread

2 G 1” sleves - stainless-steel heating coil inlet and outlet

1.5 - Packaging

Tanks are delivered standing, each screwed to its pallet, packed in bubble wrap.
Included in the package are all components to be 

fi

tted on the tank. Insulation is packaged sepa-

rately.

2 - General Information

This Owners Manual is an integral and important part of the product and must be handed over to 
the User. Read carefully the instructions in this Manual as they contain important information con-
cerning safety, installation, operation and maintenance. Keep this Manual for later reference.

This appliance is designed to accumulate heating water and distribute it subsequently. It shall be 
connected to a heating system and heat sources. This appliance is also suitable for instantaneous 
water heating.

Using the Thermal Store for other purposes than above described is forbidden and the manufac-
turer accepts no responsibility for damage caused by improper or wrong use.

The output of heat sources not equipped with their own safety valve and connected to the tank 

fi

tted with the enclosed safety valve shall never exceed 110 kW.

Summary of Contents for VEGA 390

Page 1: ...VEGA 390 THERMAL STORE with stainless steel DHW coil EN v 1 3 Installation and Operation Instructions...

Page 2: ...5 5 1 Mounting pump stations and accessories onto VEGA 390 6 5 2 Connecting heating circuits 17 5 3 Connecting a solar circuit 17 6 Installation and Commissioning 18 6 1 Connecting heat sources 18 6...

Page 3: ...tly on the tank the second main layer features thermal conductivity l 0 032 W m K the third layer is a hard glossy washable surface The total insulation thickness is 100 mm 1 4 Connection points 1 top...

Page 4: ...changer volume 23 l DHW heat exchanger surface area 6 sqm Max working temperature in tank 95 C Max working temperature in DHW heat exchanger 95 C Max working pressure in tank 4 bar Max working pressur...

Page 5: ...he tank The heat exchanger connects to a cold water inlet with a G1 nipple and to DHW with the other one As soon as hot water is drawn from an outlet cold water flows into the immersed heat ex changer...

Page 6: ...1 2 stainless steel 3 pcs 12714 Cover for 2 circuit pump station for 380l Thermal Store 1 pcs 12223 Front insulation for cover for 2 circuit pump station 1 pcs 12721 Top insulation for 2 circuit pump...

Page 7: ...ealant or with the gaskets included in separate kits 1 Remove the tank from its pallet and place it to its approximate position shift the bottom insulation under the tank 2 Slide the insulation insert...

Page 8: ...76 Remove the zone valve actuator from the assembly prior to mounting Port A of the zone valve shall be oriented upwards 6 Loosen the clamps fit the metal sheet against the four pins code 12710 from K...

Page 9: ...690 8 Fit the pump station with 4 way mixing valves code 12224 or 12225 Join it with the earlier fitted Angled Ball Valve Assy and tighten the clamps 9 Fit 1 Valve Assy out to h circuit code 13479 and...

Page 10: ...Assy out to h circuit code 13497 11 Fit the Safety Drain Valve Assy code 13529 into the sleeve 12 Fit the sheaths code 154 into the dedicated sleeves and plug 1 2 with gasket code 9097 Plug 1 2 code...

Page 11: ...11 13 Fit the Zone Valve Assy out to HP code 13477 Remove the zone valve actuator prior to fitting Port A of the zone valve shall be oriented upwards 14 Fit the 1 Elbow Assy out to HP code 13494...

Page 12: ...12 15 Fit the thermometer code 10474 from the Kit 13237 16 Fit the 1 Elbow Assy in from HP code 13478...

Page 13: ...sulation circa 550 mm long 1 tube 5 4 DN 25 125 mm long code 13484 insulation circa 200 mm long 18 Locate the Zone Valve Assy fitted as shown in point 13 and the Elbow Assy fitted as shown in point 14...

Page 14: ...fitted as shown in point 11 Connect these two using the dedicated 1 pipe 690 mm long code 13489 21 Locate the 1 hex nipple in the Zone Valve Assy fitted as shown in point 13 and the 1 Elbow Assy fitte...

Page 15: ...code 6971 all included in Kit 13237 23 Push the front insulation onto the pump station with 4 way valves 24 Connect the terminals of the pumps push the cables behind the insulation 25 Fit the plastic...

Page 16: ...16 Completely fitted tank Safety high limit thermostat for electric heating elements optional part...

Page 17: ...o connected to a solar thermal system An extra flange and a tube heat exchanger coil will be needed depending on the output of the solar thermal system All connecting pipes between the tank and solar...

Page 18: ...ating elements shall be installed together with a safety temperature limiter An el heating element shall be wired by qualified staff only 6 4 Connecting sanitary water piping DHW piping shall be done...

Page 19: ...Installation Manual was not respected the product was used for other purposes than intended Warranty does not cover usual wear and tear damage caused by fire water electricity or a natural disaster de...

Page 20: ...04 2016 REGULUS spol s r o Do Kout 1897 3 http www regulus eu 143 00 Praha 4 E mail sales regulus eu CZECH REPUBLIC...

Reviews: