IR12 CTC cont fireplace module

Backup of circulation pump of a fireplace.

MAINS

230 V, 50 Hz

CIRCUIT WITHOUT 

BACKUP

IR 12 SMART 

CONTROLLER

PUMP WITHOUT 

BACKUP

DETAILED PIC. SHOWING TERMINAL BOARDS MARKING AND WIRING

PUMP WITH 

BACKUP

CIRCUIT WITH 

BACKUP

Do respect the separation between the circuits with and without backup. 

Not only for the live wire but also for the neutral one!

PG 600 S BACKUP POWER SUPPLY

BATTERY

Summary of Contents for PG 600 S

Page 1: ...www regulus eu PG 600 S PG 600 S EN Installation and Operation Manual PG 600 S BACKUP POWER SUPPLY...

Page 2: ...TURES DESCRIPTION 5 1 1 GENERAL DESCRIPTION 5 1 2 FRONT PANEL 6 1 3 REAR PANEL 9 2 INSTALLATION 9 2 1 RECOMMENDED WIRING 9 2 2 TURNING PG 600 S ON WITH NO GRID POWER 15 2 3 TURNING PG 600 S OFF 15 3 O...

Page 3: ...a sufficiently spacious and ventilated room enabling good access It shall never be exposed to weather Whenever handling a battery and PG 600 S the PG 600 S shall be turned off and disconnected from th...

Page 4: ...se gases escape into the air In batteries with pressure valves most of these gases recombine inside the battery and just a very small portion escapes into the air Always ensure good ventilation for ba...

Page 5: ...signed for manual control do not use sharp or pointed items PG 600 S is not designed for operation in explosive environment Both PG 600 S and the battery shall be placed in a sufficiently ventilated s...

Page 6: ...and the red LED flashes At the same time the symbol Overload warning The audio alarm sounds every 2 s and the red LED flashes At the same time the symbol Adjustment warning The audio alarm sounds eve...

Page 7: ...presented in the table below Optional info Display Imput Input voltage 230 V input frequency 50 Hz Battery Battery voltage 24 8 V battery current 1 A Output Output voltage 230 V output frequency 50 Hz...

Page 8: ...blink 75 100 The bottom three bars are lit and the top one blinks Float mode Batteries are fully charged All bars are lit Battery mode Info will contain data on the battery capacity Battery voltage D...

Page 9: ...the internal cooling fan also starts running 5 Connect your pump or another load by plugging its cable into the socket of PG 600 S It is inevitable to stick to a TN S wiring system 6 Press and hold O...

Page 10: ...V 50 Hz CIRCUIT WITHOUT BACKUP IR 12 SMART CONTROLLER PUMP WITHOUT BACKUP DETAILED PIC SHOWING TERMINAL BOARDS MARKING AND WIRING PUMP WITH BACKUP CIRCUIT WITH BACKUP Do respect the separation betwee...

Page 11: ...HOUT BACKUP IR 12 SMART CONTROLLER PUMP WITHOUT BACKUP DETAILED PIC SHOWING TERMINAL BOARDS MARKING AND WIRING PUMP WITH BACKUP CIRCUIT WITH BACKUP Do respect the separation between the circuits with...

Page 12: ...230 V 50 Hz CIRCUIT WITHOUT BACKUP IR 12 SMART CONTROLLER PUMP WITHOUT BACKUP DETAILED PIC SHOWING TERMINAL BOARDS MARKING AND WIRING PUMP WITH BACKUP CIRCUIT WITH BACKUP Do respect the separation be...

Page 13: ...13 Fireplace Backup of a fireplace circulation pump with flue thermostat MAINS 230 V 50 Hz PUMP WITH BACKUP FLUE THERMOSTAT BATTERY PG 600 S BACKUP POWER SUPPLY...

Page 14: ...r Pump backup STDC TRS etc controller Backup of a PWM controlled pump PG 600 S BACKUP POWER SUPPLY BATTERY PG 600 S BACKUP POWER SUPPLY BATTERY MAINS 230 V 50 Hz STDC TRS etc controller MAINS 230 V 50...

Page 15: ...remain off unless the inner temperature of PG 600 S starts rising In case of a power supply breakdown the fan turns on cooling the inverter if needed When power supply is restored the timer turns on...

Page 16: ...V default value is 10 5 V 23 Backlight OFF default ON 24 Sound alarm ON default OFF 29 Charging from the mains Charging from the mains enabled default Charging from the mains disabled 30 UPS function...

Page 17: ...ted output 06 Too high output voltage from the UPS 07 Overload 11 Main relay faulty 41 Too low input voltage 42 Too high input voltage 43 Too low input frequency 44 Too high input frequency 45 Automat...

Page 18: ...age Check battery technical data Fault code 04 Too low battery voltage Check battery technical data Fault code 05 Short circuited output Disconnect the load and restart Fault code 06 UPS output voltag...

Page 19: ...utput waveform backup mode 16 4 kg 39 4 kg dimensions d x w x h weight ambient working temperature ambient relative humidity noise level Battery Type nominal voltage number capacity 18 Ah 12 V 44 Ah 1...

Page 20: ...2018 We reserve the right to errors changes and improvements without prior notice REGULUS spol s r o E mail sales regulus eu Web www regulus eu v1 1 12 2018...

Reviews: