background image

www.regulus.eu

CSE2 MIX F G60 1F

CSE2 MIX F G60 1F

EN

Installation and Operation Manual

CSE2 MIX F G60 1F PUMP STATION

Summary of Contents for CSE2 MIX F W 1F

Page 1: ...www regulus eu CSE2 MIX F G60 1F CSE2 MIX F G60 1F EN Installation and Operation Manual CSE2 MIX F G60 1F PUMP STATION ...

Page 2: ...STATION COMPONENTS 4 3 1 GRUNDFOS UPM3 AUTO 25 60 PUMP 5 3 2 MIXING VALVE WITH ACTUATOR 8 3 3 CHECK VALVE 8 3 4 FILTER WITH MAGNET 8 3 5 BALL VALVES 8 4 EXAMPLES OF PUMP STATION CONNECTION 10 5 PUMP STATION INSTALLATION 12 6 TEMPERATURE SENSOR INSTALLATION 13 7 OPTIONAL ACCESSORIES 15 APPENDIX ACTUATOR ADJUSTMENT 19 ...

Page 3: ... valve w actuator thermometers insulation Working fluid water antifreeze heat transfer fluid for heating systems Installation vertically on a wall or manifold 125 mm pitch Connections 4 x G 1 F Code 19103 Data for CSE2 MIX F G60 1F Pump Station Fluid working temperature 5 95 C Max working pressure 10 bar Min working pressure 0 5 bar Ambient temperature 5 40 C Max relative humidity 80 non condensin...

Page 4: ...ter at the heating circuit flow 3 Grundfos UPM3 AUTO 25 60 circulation pump 4 Mixing valve w actuator 5 T piece with check valve 6 Filter w magnet 7 Lever for ball valves 8 Ball valve w sheath for temperature sensor heating circuit return 9 Ball valve w sheath for temperature sensor heating circuit flow 9 3 2 4 3 5 8 7 1 6 4 ...

Page 5: ...mp Connection socket for power supply A and signal transmission B not used in this pump power supply connector A N blue L brown PE yellow green Pump control The circulation pump can be controlled by selecting a suitable profile and performance curve Performance curves Line type Profile Constant speed Proportional pressure Constant pressure ...

Page 6: ...iable characteristics e g pumps for heating up a HW storage tank or for a circuit with a heat exchanger Head pressure remains the same in the whole range of flow rates does not change with the system pressure drop Pump operating point moves on the selected constant pressure curve depending on the current system pressure drop CONTROL MODE DESCRIPTION Constant pressure I The lowest curve of constant...

Page 7: ...ettings Display WARNING LEDs may be turned by 90 or 180 or mirrored depending on the specific pump type During operation the selected pump profile is indicated by green LEDs and the power level by yellow LEDs Setting selection Pump profiles can be switched by pressing the integrated button The pump profiles change in a closed loop in the order shown in the table Error Display DISPLAY ERROR Seized ...

Page 8: ...hat attracts magnetic particles The filter needs to be checked regularly and cleaned when needed Turn off the circulation pump close the ball valve upstream of the filter Water inlet downstream of the magnet is closed by the check valve Unscrew the filter lid remove the stainless steel strainer and flush thoroughly Wipe the impurities on the magnet and re assemble the filter by inserting the strai...

Page 9: ...9 Regulus CSE2 MIX F G60 1F www regulus eu OPEN CLOSED groove in the flow direction groove perpendicular to the flow direction ...

Page 10: ...uit 1 CSE2 7 pump station for DHW recirculation CSE TVMIX ZV 8 safety kit for HW storage tank 9 DHW expansion vessel 10 RegulusBOX indoor unit SV cold water TV hot water CV hot water recirculation ÚT central heating heating system KK ball valve ZV check valve AOV automatic air vent valve PTR pressure temperature relief valve REDV pressure reducing valve optional VK drain valve SVE expansion vessel...

Page 11: ...HW recirculation CSE TV ZV 8 boiler natural gas electric 9 pump station for heating circuit 2 CSE2 MIX 10 pump station for heating circuit 1 CSE2 SV cold water TV hot water CV hot water recirculation ÚT central heating KK ball valve ZV check valve AOV automatic air vent valve PTR pressure temperature relief valve REDV pressure reducing valve optional VK drain valve SVE expansion vessel service val...

Page 12: ... 80 mm The package includes a mounting kit that is used to fix the pump station to the intended place The mounting kit includes Screw 5x50 round head 2 pcs 6 4 stainless steel washer DIN 9021 A2 2 pcs Wall plug 8mm TX 2 pcs 340 360 125 245 Permitted and prohibited positions of the pump station Permitted position Conditionally permissible positions Prohibited position may be used when a filter is r...

Page 13: ... pulled out In the top and bottom section of the insulation there are passages to run the cables through then it is necessary to cut the appropriate part of the passage lock from the front part of the insulation with a knife so that the exiting cables are firmly wrapped around by the lock 1 Temperature sensor placement 2 Securing the temperature sensor with the screw 3 Running the sensor cable thr...

Page 14: ... 14 Regulus CSE2 MIX F G60 1F www regulus eu 4 Trimming the cable passage lock 5 Installed sensors ...

Page 15: ...CCESSORIES The following optional accessories are available for the pump station A Filter replacement section for CSE2 Code 19017 Loosen the unions above and under the filter Remove the filter and mount the filter replacement section code 19017 in its place ...

Page 16: ...www regulus eu B Ball Valve w drain valve Fu F Code 17415 and Union 1 Fu M incl gasket Code 15695 Remove both the connecting fittings Install the union 15695 in their place then attach the ball valve w drain valve 17415 to the union ...

Page 17: ...sket for return line of CSE2 pump stations Code 18653 and Union 1 Fu M extended incl gasket for flow line of CSE2 pump stations Code 18797 Remove both the connecting fittings Install the extended union with check valve 18653 to the return line Install the extended union 18797 to the flow line ...

Page 18: ...ulus CSE2 MIX F G60 1F www regulus eu D Union to connect CSE2 to 5 4 manifold 1 x5 4 Fu F Code 17920 Remove both the connecting fittings Replace them with the union 17920 intended for connection to a manifold ...

Page 19: ... removed e g to be replaced 1 When fitting the actuator turn the D shaft in such a manner that the valve member is between inlets 2 and 3 at an angle of 45 2 Fit the plastic adapter on the shaft The flat edge of the shaft and the arrow on the plastic adapter are located on the same side as the valve member valve member position D shaft D shaft valve member position arrow on plastic adapter ...

Page 20: ...to the right by 45 the path 3 is closed and when turned to the left by 45 the path 2 is closed Having performed the check tighten the fastening screw and switch back to motorized control 5 The actuator shall be installed in the same manner as in the figure control mode switch line in sightglass motorized control manual control control knob 2022 We reserve the right to errors changes and improvemen...