6. Installation Options

The solar pump station is designed to be mounted on a wall or on a tank. There are two fixing ope-

nings in the rear part of the insulation. The lower one is accessible only when the electronic contro-

ller is removed from rear part of the insulation (see the pic. below).

The supply involves an installation kit that is used to fix the pump station in its place.

7. Pump Station Connection Diagram

OPENINGS  IN  THE  BACK 

PLATE  FOR  FIXING  THE 

PUMP STATION

SRS1 T  

CONTROLLER

KEY

hot water storage tank

ETT-N electric heating element

solar collectors

solar pump station

pump station for DHW recirculation – CSE  

 

TVMIX ZV

safety kit for HW storage tank

solar expansion vessel

DHW expansion vessel

SV 

cold water

TV  

hot water

CV 

hot water recirculation

KK 

ball valve

ZV 

check valve

AOV 

automatic air vent valve

PTR 

pressure temperature relief valve

REDV 

pressure reducing valve (optional)

VK 

drain valve

SVE 

expansion vessel service valve

ZÁS 

power socket, 230 VAC, 50 Hz

S1 

collector temperature sensor Pt1000

S2 

HW storage tank temperature sensor Pt1000

R1 

R1 relay of SRS1 T controller (potential-free)

Summary of Contents for CSE SOL G SRS1 T-E

Page 1: ...www regulus eu CSE SOL G SRS1 T E CSE SOL G SRS1T E EN Installation and Operation Manual CSE SOL G SRS1 T E SOLAR PUMP STATION...

Page 2: ...essary to connect only the collector temperature sensor An electric heating element of up to 3 kW output can be connected to the pump station The pump station is equipped with a special socket for thi...

Page 3: ...at 50 C 1 2 bar at 90 C 1 8 bar at 110 C this condition is met for current installations when the initial system pressure is set following the formula see the Instructions for solar collectors p 1 3...

Page 4: ...N THE UPPER PART OF INSULATION 7 PRESSURE GAUGE 8 EXPANSION VESSEL CONNECTION POINT 3 4 M 9 6 BAR SAFETY VALVE 10 FILLING BALL VALVE 11 SPANNER FOR CONTROL OF BALL VALVE W SIDE OUTLET 12 DRAIN BALL VA...

Page 5: ...r is turned to the left Before closing opening the ball valve it is necessary to remove the front part of the insulation As a result closing the system is reserved for installation or service technici...

Page 6: ...STATION SRS1 T CONTROLLER KEY 1 hot water storage tank 2 ETT N electric heating element 3 solar collectors 4 solar pump station 5 pump station for DHW recirculation CSE TVMIX ZV 6 safety kit for HW st...

Page 7: ...7 1 Overview of Hydraulic Variants 1 3 5...

Page 8: ...controlled internally without PWM signal by selecting a proper mode and pump curve externally by PWM C control signal profile for solar systems WARNING IMPORTANT The pump permits to be controlled als...

Page 9: ...n the current system pressure drop CONTROL MODE DESCRIPTION Constant pressure I The lowest curve of constant pressure II The middle curve of constant pressure III The highest curve of constant pressur...

Page 10: ...DE green LED FLASHING INTERNAL 1 Proportional pressure AUTOADAPT 2 Constant pressure AUTOADAPT 3 Proportional pressure I 4 II 5 III 6 Constant pressure I 7 II 8 III 9 Constant speed I 10 II 11 III DIS...

Page 11: ...mance Setting selection To select your desired setting press the button repeatedly until you find the setting you need see the table above If you pass the desired setting you have to go one more round...

Page 12: ...o the fill and drain ball valves using hoses see Chap 4 and open these valves After filling the solar thermal system close the fill and drain ball valves disconnect the hoses and re open the ball valv...

Reviews: