64
and will be switched off again if the temperature reaches demand (+
switch-off difference).
Call for heat from Thermostat 1 (2) (on/off)
.................................... Switch-off temperature for Thermostat 1 (2) will be taken over as the
desired temperature for heat sources. Valid only if Thermostat 1 (2) is
set in “heating” mode. When
Timer
function is also On, the request will
be taken over during active time period only.
Differential thermostat
Differential thermostat between sensors 1 and 2.
diff. on (°C)
.................
Switch-on difference between temperatures.
diff. off (°C)
.................
Switch-off difference between temperatures.
Delay
Output switch-on delay function.
period (minutes)
........
Delay time in case when all the preceding functions are switched on.
Overrun
Output switch-off delay function.
overrun (minutes)
......
Output overrun time after the preceding functions are switched off.
Timer
A simple timer with two time periods.
on 1 (hh:mm)
.............. The first period switch-on time.
off 1 (hh:mm)
............. The first period switch-off time.
on 2 (hh:mm)
.............. The second period switch-on time.
off 2 (hh:mm)
............. The second period switch-off time.
reset state of T1&T2 with every start of the period of the program
.................................... When this function is On, at every start of time period in time program
the state of both thermostats, T1 and T2, will be reset according to the
current temperatures.
Using the UNI function for pool heating
To activate and display the pool in the system diagram, it is necessary to use the web interface
and set the value 1 (= pool) in the configuration settings of the UNI module. Subsequently, the
required pool heating parameters can be set.