n
Printing position
0, 48
Not printed
1, 49
Above the bar code
2, 50
Below the bar code
3, 51
Both above and below the bar code
HRI indicates Human Readable Interpretation.
[Notes]
HRI characters are printed using the font specified by GS f.
[Default]
n = 0
[Reference]
GS f, GS k
GS f n Select font for Human Readable Interpretation (HRI) characters
[Name]
Select font for Human Readable Interpretation (HRI) characters
[Format]
ASCII
GS
f
n
Hex
1D
66
n
Decimal
29
102
n
[Range]
n = 0, 1, 48, 49
[Description]
Select a font for the HRI characters used when printing a bar code. n selects a font from the
following table:
n
Font
0, 48
Standard ASCII characters (12 × 24)
1, 49
Compressed ASCII characters (9 × 17)
[Notes]
HRI indicates Human Readable Interpretation.
HRI characters are printed at the position specified by GS H.
[Default]
n = 0
[Reference]
GS H, GS k
GS h n Select bar code height
[Name]
Select bar code height
[Format]
ASCII
GS
h
n
Hex
1D
68
n
Decimal
29
104
n
[Range]
1 ≤ n ≤ 255
[Description]
Select bar code height
n specifies the number of dots in the vertical direction.
[Default]
n = 60
[Reference]
GS k
①GS k m d1...dk NUL②GS k m n d1...dn Print bar code
[Name]