background image

RA-MINI ALU

 IN-LINE ACTUATOR SERIES

6

04. Warranty

All REGNER® products have a warranty against 

manufacturing defects. The warranty period begins 

on the purchase date of the product. The seller is 

responsible for nonconformities that become appar-

ent within the time stipulated by the applicable law.

04.01. Warranty Exclusions

REGNER® is entitled to deny any warranty if:

• The actuator has not been used correctly or its 

usage specifications (load, temperature, duty cycle, 

voltage, current, etc.) have not been respected.
• The actuator has not been maintained correctly.
• The actuator has been manipulated.
• The actuator has been exposed to violent or abra-

sive treatment.

Nonconformities due to reasonable wear and tear 

of the actuator over time (such as faded paint) are 

excluded from warranty.

REGNER® reserves the right to request the return 

of all allegedly defective products for testing and 

verification. 

Any additional warranty obligations for parts 

replaced free of charge or for any service provided 

without charge under this warranty shall be exclud-

ed. The warranty period for parts replaced under 

warranty will end on the expiry date of the warranty 

period of the main product.

05. 

Specifications

05.01. Label

Batch No: XXXXXX

Customer Ref.: XXXXX 

RA-MINI ALU 45.30.87.350.D4

www.regner.es

01. RA-MINI ALU 45.30.87.350.D4

• RA-MINI ALU: actuator type
• 45: max. load (N)
• 30: stroke length (mm)
• 87: retracted length, center to center (mm)
• 350: cable length (mm)
• D: rod end (D = standard / H = clevis)
• 4: mounting hole diameter (mm)
• 0: Position control (0 = Limit switches only, P = 

potentiometer).

02. Customer Ref.: XXXXXXX

Optional. Customer reference for the product.

03. Batch No.: XXXXXX

Identification number assigned to a particular lot 

of products that enables REGNER® to control their 

quality and trace their constituent parts.

04. Symbols

Symbol

Norms

WEEE Directive 2002/96/EC

Compliance to all relevant CE directives

Summary of Contents for RA-MINI ALU Series

Page 1: ...RA MINI ALU IN LINE ACTUATOR SERIES User Manual www regner es...

Page 2: ...l rights reserved Specifications are subject to change without notice It is the responsibility of the user to determine the suitability of REGNER products for a specific application No part of this pu...

Page 3: ...E ACTUATOR SERIES 3 00 Contents 01 Preface 4 02 Safety 4 03 Declaration of Conformity 5 04 Warranty 6 05 Specifications 6 06 Installation 9 07 Maintenance 10 08 Troubleshooting 11 09 Application Polic...

Page 4: ...off the main power supply when the actuator is not in use to prevent unintentional operation Do not exert force on the side of the actuator Make sure that the cable cannot be pressed upon pulled or su...

Page 5: ...electronic products with respect to the restriction of hazardous sub stances In accordance with the provisions of the directives 2014 30 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February...

Page 6: ...allegedly defective products for testing and verification Any additional warranty obligations for parts replaced free of charge or for any service provided without charge under this warranty shall be...

Page 7: ...ing current 200 mA Overcurrent prot 116 mA Integrated limit switch Integrated in Limit Switches version Not available in Potenti ometer version Connector Molex 39 01 3029 IP rating IP54 Retracted leng...

Page 8: ...overcurrent protection feature will cut off the current at 3 A to protect the actuator The overcur rent protection system resets after 10 seconds when activated to enable normal operation 05 06 Elect...

Page 9: ...ve freely along the full stroke length both in the development phase and during normal operation Examine the area around the housing and see that no components can get trapped and damage the applicati...

Page 10: ...ion use a fuse between the actuator and the power source Do not work on the actuator or the wiring with the power switched on Wire cross sections To avoid malfunctions due to voltage drops the cross s...

Page 11: ...orce or runs in smaller steps 1 Excessive load 2 Voltage drop in the cable long cables may affect performance 3 Current cut off due to ex cessive load A Wait for the overcurrent protection system to r...

Page 12: ...RA MINI ALU IN LINE ACTUATOR SERIES 12...

Page 13: ...MAGPOTUSERMANUAL Ripoll s 4 17181 Aiguaviva Girona SPAIN Tel 34 972 476 911 Fax 34 972 475 803 info regner es www regner es...

Reviews: