Preset Configurations

High-speed 
reducer 
(100:1)

Standard 
reducer 
(210:1)

High-force 
reducer 
(298:1)

Max. peak 
load

20 N at 

9.0 mm/s

45 N at 

3.5 mm/s

70 N at 

3.6 mm/s

Rated load

7.5 N at 

12.5 mm/s

20 N at 

5.0 mm/s

30 N at 

4.4 mm/s

Max. speed

 

(no load)

14.7 mm/s

5.9 mm/s

4.6 mm/s

Max. 
current

114 mA

76 mA

114 mA

05.04. Force Curves

Use in the dashed area is not recommended.

The above values are with a room temperature of 20 °C.

Speed - Force

Current - Force

Speed (mm/s)

Force (N)

0

3

6

9

12

15

0 10 20 30

80

70

60

50

40

0

30

60

90

120

150

Current (mA)

Force (N)

0 10 20 30

80

70

60

50

40

High force reducer

Standard reducer

High speed reducer

05.05. Overcurrent Protection

In the event of an obstruction or an excessive load, 

the overcurrent protection feature will cut off the 

current at 3 A to protect the actuator. The overcur-

rent protection system resets after 10 seconds when 

activated to enable normal operation.

05.06. Electronic Limit Switches (opt.)

When the actuator reaches its fully extended or 

fully retracted positions, an electronic limit switch 

automatically cuts off the current to prevent damage 

to the motor. When it reaches either stroke end point, 

the actuator can move only in the opposite direction, 

until it is separated from the limit and it can resume its 

normal function and move freely in either direction.

05.07. Position feedback (opt.)

The position feedback potentiometer is feeded with a 

5 VDC voltage. Depending on the position of the rod, 

the potentiometer sends an analog signal between 

0 VDC (actuator fully retracted) and 5 VDC (actuator 

fully extended).

05.08. Dimensions

Retrac

ted length (center to center): 57.5 + stroke

64 + stroke

All measurements are in mm.

Summary of Contents for RA-MINI ALU Series

Page 1: ...RA MINI ALU IN LINE ACTUATOR SERIES User Manual www regner es...

Page 2: ...l rights reserved Specifications are subject to change without notice It is the responsibility of the user to determine the suitability of REGNER products for a specific application No part of this pu...

Page 3: ...E ACTUATOR SERIES 3 00 Contents 01 Preface 4 02 Safety 4 03 Declaration of Conformity 5 04 Warranty 6 05 Specifications 6 06 Installation 9 07 Maintenance 10 08 Troubleshooting 11 09 Application Polic...

Page 4: ...off the main power supply when the actuator is not in use to prevent unintentional operation Do not exert force on the side of the actuator Make sure that the cable cannot be pressed upon pulled or su...

Page 5: ...electronic products with respect to the restriction of hazardous sub stances In accordance with the provisions of the directives 2014 30 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February...

Page 6: ...allegedly defective products for testing and verification Any additional warranty obligations for parts replaced free of charge or for any service provided without charge under this warranty shall be...

Page 7: ...ing current 200 mA Overcurrent prot 116 mA Integrated limit switch Integrated in Limit Switches version Not available in Potenti ometer version Connector Molex 39 01 3029 IP rating IP54 Retracted leng...

Page 8: ...overcurrent protection feature will cut off the current at 3 A to protect the actuator The overcur rent protection system resets after 10 seconds when activated to enable normal operation 05 06 Elect...

Page 9: ...ve freely along the full stroke length both in the development phase and during normal operation Examine the area around the housing and see that no components can get trapped and damage the applicati...

Page 10: ...ion use a fuse between the actuator and the power source Do not work on the actuator or the wiring with the power switched on Wire cross sections To avoid malfunctions due to voltage drops the cross s...

Page 11: ...orce or runs in smaller steps 1 Excessive load 2 Voltage drop in the cable long cables may affect performance 3 Current cut off due to ex cessive load A Wait for the overcurrent protection system to r...

Page 12: ...RA MINI ALU IN LINE ACTUATOR SERIES 12...

Page 13: ...MAGPOTUSERMANUAL Ripoll s 4 17181 Aiguaviva Girona SPAIN Tel 34 972 476 911 Fax 34 972 475 803 info regner es www regner es...

Reviews: