![REGLOPLAS 150smart Operating Instructions Manual Download Page 28](http://html1.mh-extra.com/html/regloplas/150smart/150smart_operating-instructions-manual_1434338028.webp)
V
11/2014
24
Maintenance
Temperature Control Unit 90smart/150smart
Technical Data 90smart/150smart
Temperature Control Unit Type
90smart
150smart
Max. outlet temperature
90 °C
90 °C/150 °C
Heat carrier/medium
Water
Oil
Filling capacity
7.0 l
7.5 l
Max. expansion volume
2.5 l
4.5 l
Heating capacity
6/9 kW
6 kW
Heating switch
SSR relay
SSR relay
Cooling capacity
51 kW (1K)
75 kW (2K)
29 kW
at outlet temperature
80 °C
140 °C
at cooling water temperature
20 °C
20 °C
Pump
type
TP20 TS22 TP20 TS22
Motor power (pump)
0.5 kW
1.1 kW
0.5 kW
1.1 kW
Max. delivery rate
60 l/min
70 l/min
60 l/min
70 l/min
Max. delivery pressure
3.8 bar
5.4 bar
3.8 bar
5.4 bar
Control System
RT34 / RT70 Control System
Measurement type (standard)
Pt100
Control voltage
115/230 V, 50/60 Hz
Input supply voltages
200-600 V
50/60 Hz
Total power
(see specification plate) (see
specification
plate)
Outlet/inlet connections (standard)
G 1/2"
G 1/2"
Cooling water supply connections
(standard)
G 1/2"
G 1/2"
Degree of protection
IP40
IP40
Dimensions W/H/D
202/560/661 mm
202/560/661 mm
Weight
approx. 44 kg
approx. 50 kg
Colour
RAL 9006/7016
RAL 9006/7016
Ambient temperature
max. 40°C
max. 40°C
Continuous sound pressure level
< 70 dB(A)