Alarm Messages
The RT70 control system can display various error messages (warnings
and alarms). Attention must be paid to these error messages without fail.
Otherwise, malfunctions of / damage to the temperature control unit and
production downtimes may result.
Pressing the
Alarm Reset
button allows you to acknowledge/reset an
alarm (e.g. switching off the horn). Only after the malfunction has been
rectified can the alarm display be cleared by once again pressing the
Alarm Reset
button.
The
Alarm Reset
button also allows manual acknowledgement of the au-
tomatic switchover (toggling) from consumer temperature control (or cas-
cade control)
Sn2
to outlet temperature control
Sn1
in the event that
sensor
Sn2
is defective or removed from the consumer.
Alarm list
Pressing the
Alarm Reset
button opens the alarm list, as long as there is
no active alarm. The last ten alarm messages are displayed in this list,
complete with date and time.
Warnings
Error message
Rectification
Service is due
Carry out maintenance procedure according to the
operating manual. Increment the parameter
Next
Maintenance
by 1000 hours
Deviation set-point value/outlet underrun
Adjust the outlet temperature and acknowledge the
fault
Deviation set-point value/outlet exceeded
Adjust the outlet temperature and acknowledge the
fault
Leak stop not possible
Reduce the temperature
Leak stop not allowed
Unit is not allowed for leak stop
Suction not possible
Switch the unit to normal operation mode
Alarms
Error message
Rectification
Level 1 underrun
Refill heat transfer medium
Toggling of heat transfer medium - unit must be re-
started
Switch the main switch off and on again
External set-point value signal interrupted or not pre-
sent
External set-point value signal must be present (if re-
quired, check external control system)
Analog option missing or defective
Connect analog option or switch off in the parameter
Hardware Options
Digital option missing or defective
Connect digital option or switch off in the parameter
Hardware Options
AD converter failure
Replace base module
Attention - temperature control cabinet too high
Place the temperature control unit in a place with low
ambient temperature
Flow switch act
Check the outlet pressure (min. 0.7 bar must be pre-
sent)
Max. temperature exceeded
Max. temperature of the heat transfer medium may