U32S-5 FPI Direct Vent Gas Insert
33
33
operatinG instructions
copY of liGHtinG instruction plate
slightly different rates which can cause "ticking"
and "cracking" sounds. You should also be aware
that as there are temperature changes within
the unit these sounds will likely re-occur. Again,
this is normal for steel fireboxes.
Blower thermodisc:
When this thermally activated switch turns ON
it will create a small "clicking" sound. This is the
switch contacts closing and is normal.
pilot flame:
While the pilot flame is on it can make a very
slight "whisper" sound.
Gas control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.
Maintenance
instructions
1)
Always turn the gas valve to off before
cleaning. For relighting, refer to lighting
instructions. Keep the burner and control
compartment clean by brushing and
vacuuming at least once a year. When
cleaning the logs, use a clean soft paint
brush as the logs are fragile and easily
damaged.
2)
Clean (never when unit is hot) appliance,
door and faceplate with a damp cloth. Never
use an abrasive cleaner. The finishes on the
door frame and faceplate may be scratched
if abrasives are used to clean them.
The heater is finished in a heat resistant
paint and should only be refinished with
heat resistant paint (not with wall paint).
Regency uses StoveBrite Paint - Metallic
Black #6309.
3)
Make a periodic check of burner for proper
position and condition. Visually check the
flame of the burner periodically, making sure
the flames are steady; not lifting or floating.
If there is a problem, call a qualified service
person.
4)
The appliance and venting system must be
inspected before use, and at least annually,
by a qualified field service person, to ensure
that the flow of combustion and ventilation
air is not obstructed.
During the annual service call, the burners
should be removed from the burner tray
and cleaned. Replace the embers but do
not block the pilot.
5)
Keep the area near the appliance clear and
free from combustible materials, gasoline
and other flammable vapours and liquids.
6)
Each time the appliance is lit, it may cause conden-
sation and fog the glass. This condensation and
fog is normal and will disappear in a few minutes
as the glass heats up.
never operate the appliance without the glass
properly secured in place or with the door open.
7)
Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to replace
nay part of the control system and any gas control
which has been under water.
8)
Periodically check the pilot flames. Correct flame
pattern has three strong blue flames: 1 flowing
around the thermopile and 1 around the thermo-
couple, and 1 flowing across the rear of the burner
(it does not have to be touching the burner).
If you have an incorrect flame pattern, contact your
Regency dealer for further instructions.
1) Push in gas control knob slightly and turn to “PILOT” position.
2) Push in control knob all the way and hold in untilthe pilot lights
up. Continue to hold the control knob in for about 20 seconds
after the pilot is lit. Release knob.
3) Push in gas control knob slightly and turn to "ON" position.
4) Turn ON the flame switch.
2) Wait five (5) minutes to clear out any gas. If you then smell gas
STOP! follow “B” in the safety information above on this label. If
you don’t smell gas, go to the next step.
3) Tu rn knob on gas control counterclockwise
to “PILOT”.
4) Pu sh in control knob all the way and hold in. Immediately push
black button on spark igniter until pilot lights. Continue to hold the
control knob in for about 1/2 minute after the pilot is lit. Release
knob and it will pop back up. Pilot should remain lit. If it goes out,
repeat steps 3) and 4).
If knob does not pop up when released, stop and immediately call
your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas control
knob to “OFF” and call your service technician or gas supplier.
5) Tu rn gas control knob counterclockwise
to “ON”.
6) Us e rocker switch to operate main burner.
DO NOT REMOVE THIS INSTRUCTION PLATE
FOR YOUR SAFETY READ BEFORE LIGHTING
A) This appliance has a pilot which must be lighted by hand, following the instructions below exactly.
B) BE FORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
-
Do not try to light any appliance
-
Do not touch any electric switch, do not use any phone in your building
-
Immediately call your gas supplier from a neighbors phone. Follow the gas supplier’s instructions.
-
If you cannot reach your gas supplier, call the fire department.
C) Us
try to
repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and
to replace any part of the control system and any gas control which has been under water.
E) Thisappliance needs fresh air for safe operation and must be installed so there are provisions adequate comb ventilation air.
918-474b
OFF
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
or additional information consult a qualified installer, service agency or gas supplier.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS APPLIANCE
THERMOPILE
ELEMENT
THERMO-
ELECTRIQUE
PILOT BURNER
VEILLEUSE
1/
NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: A S5601-2004, New Zealand: NZS 5261)
FOR UNITS NOT EQUIPPED WITH ELECTRIC SPARK:
. Keep burner
appliance.
STOP! Read the safety information above on this label.
FOR ALL PROPANE UNITS AND
UNITS EQUIPPED WITH ELECTRIC SPARK BOXES:
1) Push in gas control knob slightly and turn clockwise
to
“OFF”. Knob cannot be turned from “PILOT” to “OFF” unless
knob is pushed in slightly. Do not force.
1) Turn off the flame switch.
2) Push in the gas control knob slightly and turn clockwise
to “OFF”. Do not force.
3) Turn off all electric power to the appliance if service is to be performed.
You may shut off the pilot during prolonged non use periods to conserve fuel.
l
WarninG: cHildren and adults
sHould Be alerted to tHe HaZards
of HiGH surface teMperature and
sHould staY aWaY to aVoid Burns
or clotHinG iGnition. YounG
cHildren sHould Be carefullY
superVised WHen tHeY are in tHe
saMe rooM as tHe appliance.
caution: anY safetY screen or
Guard reMoVed for serVicinG an
appliance Must Be replaced prior
to operatinG tHe appliance.
clotHinG or otHer flaMMaBle
Material sHould not Be placed
on or near tHe appliance.