34
U32S-5 FPI Direct Vent Gas Insert
Maintenance
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1)
Check the Venting System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2)
Remove the Termination Cap, and shine a
flashlight down the Vent. Remove any bird
nests, or other foreign material.
3)
Check for evidences of excessive condensation,
such as water droplets forming in the inner
liner, and subsequently dripping out the joints,
Continuous condensation can cause corrosion
of caps, pipe, and fittings. It may be caused
by having excessive lateral runs, too many
elbows, and exterior portions of the system
being exposed to cold weather.
4)
Inspect joints, to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports
such as Wall Straps, or plumbers' tape for
rigidity.
Glass Gasket
If the glass gasket requires replacement use glass
gasket (Part # 936-155).
door Glass
Your Regency insert is supplied with high
temperature, 5 mm Neoceram ceramic glass
Top View of pilot flame
Top View of pilot flame
Incorrect flame pattern will have small, probably
yellow flames, not coming into proper contact
with the rear of the burner or thermopile.
that will withstand the highest heat that your unit
will produce. If your glass requires cleaning, we
recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials. Do not clean the glass when hot.
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only, and follow our step-by-step
instructions for replacement.
Warning: do not operate appliance
with glass panels removed, cracked
or broken. Replacement of the glass
should be done by a licensed or
qualified service person.
caution: Wear gloves when removing damaged
or broken glass.
flush Glass replacement
Remove the flush door front (as per instructions in
section "Standard Flush Door"). Remove the 4 glass
clips from each corner. Slide in the new replacement
glass. Push the 4 glass clips back onto the frame.
General Vent
Maintenance