Regency P48 Zero Clearance Direct Vent Gas Fireplace

32

INSTALLATION

WIRING DIAGRAM

CAUTION: Label all wires
prior to disconnection
when servicing controls.
Wiring errors can cause
improper and dangerous
operation.

No electrical power supply is required for the
gas control to operate. 120 Volt AC power is
needed for the fan switch and blower. The fan
can be hard wired if desired. A terminal block
is provided on the left hand side of the unit. A
three wire power cord can also be used and
plugged into a suitable receptacle.

(Do not cut the ground terminal off under
any circumstances.)

NOTE: Even if the fan is not purchased with the
unit, it is still a good idea to hardwire the terminal
block in case the fan is installed at a later date.

** However DO NOT leave this connection
live until the fan is installed.**

Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.

Ground

Green

Neutral

Live

Black

Red

Red

Fan Thermodisc

(normally open)

Ground

ON

OFF

Rotary Speed

Control

120V AC
60 Hz

Fan

Lockwasher

Fan

ground wire

Nut

#8 Ground Lug

(for mobile home)

Star washer

Piezo

Ignitor

To Thermocouple IN

Pilot

Assembly

H

I

LO

OFF

ON

P

IL

O

T

Gas

Pilot

Thermopile

Thermocouple

Electrode

Remote Transmitter

(Optional)

ON

OFF

Regency

Remote Receiver

or Thermostat

(Millivolt) (Optional)

Brown

Red

T-Stat

Black

White

"S.I.T" Valve

Burner ON

OFF

Thermostat

(To THTP)

(To TH)

White

Gas
In

Summary of Contents for P48-LP

Page 1: ...allation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire...

Page 2: ...4 CFR Part 3280 or the current Standard of Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appliance installation must comply with the manufacturer s installation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the cu...

Page 3: ...nty Warranty 47 Safety Label SafetyLabel 4 Installation ImportantMessage 5 Before You Start 5 GeneralSafetyInformation 5 Installation Checklist 5 ManufacturedMobileHome AdditionalRequirements 6 Unit Specifications 6 LocatingYourStove 6 Optional Duct System Kit 6 Optional Heat Release Kit 6 Hearth 6 Clearances 7 Mantels 8 MantelLegClearances 8 FramingandFinishing 9 Top Assembly Nailing Strips 10 Ve...

Page 4: ...6 tu h kW 0 4500 ft pi 0 1372 m APPAREIL FONCTIONNANT AU NATURAL GAZ CONCU POUR ETRE POELE Mod le P48 NG Pression d allimentation minimum Pression à la tubulure d chappement lev e Pression à la tubulure d chappement basse Grandeur de l injecteur D bit minimum selon D bit maximum selon l altitude é é é é é é é Calorifique Calorifique MAY BE INSTALLED IN MANUFACTURED MOBILE HOMES AFTER FIRST SALE Li...

Page 5: ...g Strips page 10 NOTE must be done before installing unit into fireplace 3 Install venting pages 20 21 4 Make gas and electrical connections Test the pilot Must be as per diagram Page 23 5 Test Gas Pressure Page 23 6 Install brick panels optional page 24 7 Install Flush Door Front Standard and optional Flush Gold Trim page 28 8 Install Optional Bay Front and optional Bay Gold Trim page 29 9 Instal...

Page 6: ...pth of the appli ance 4 The P48 Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A B C D See Diagram 1 HEARTH A hearth is not mandatory but is recommended for aesthetics and for added safety 5 This appliance is Listed for bedroom instal lations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes ...

Page 7: ... Combustibles from Back 0 0mm Side 0 0mm Floor 0 0mm Minimum Clearance from Top of Front Facing Mantel min 8 203mm Ceiling 39 990mm from top of front facing above louvers Side Wall 6 152mm Horizontal Vent Clearances Top 2 1 2 64mm Side 1 1 2 38mm Bottom 1 1 2 38mm Vertical Vent Clearances 1 1 4 32mm Alcove Clearances Max Depth 36 914mm Min Width 60 1524mm Min Height 80 2032mm Caution Requirements ...

Page 8: ... framing is made of metal studs covered with a non combustible board This drawing is to scale at 1 6 one inch 6 inches Mantel can be installed anywhere in shaded area using the above scale for units with the Flush Front and with the optional Bay Front Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discol our Maximum 1 1 2 projection at 3 minimumc...

Page 9: ...insulate the enclosure to the same degree as the rest of the house apply vapour barrier and drywall as per local installation codes Do not insulate the fireplace itself 4 The unit does not have to be completely enclosed in a chase The clearance on top of the unit from the top standoffs is 0 so combustible building materials can be laid directly on top of the standoffs You must maintain clearances ...

Page 10: ...top before unit is slipped into position TopStandoffAssembly The top standoffs are shipped in a flat position and must be folded into shape and attached 1 Remove the standoffs from the fireplace top 2 Take each standoff and bend into the cor rect shape Bend up at the bend lines until the screw holes in the standoff and the pre punched screw holes on the fireplace top line up 3 Attach the standoff ...

Page 11: ...33cm G Clearance to inside corner 13 33cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent outlet min 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm L Clearance to a mechanical air supply inlet min 72 1 8m M Clear...

Page 12: ...1 8 plated screws 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 10 vinyl siding standoff If longer runs are needed the Regency Direct Vent system Flex Part 946 616 includes all the parts needed to install the P48 with a maximum 10 run 1 8 dia flexible liner 10 ft length 2 5 dia flexible liner 10 ft length 3 spring spacers 7 4 thimble 2 5 AstroCap XL termination cap 1 6 screws 12 7 tube of Mil...

Page 13: ...ut siding and add 2 inches Flat Wall Installation Wall Thickness Vent Length inches Required inches 4 5 1 2 none 7 8 1 2 6 10 11 1 2 9 9 14 1 2 12 15 23 1 2 11 14 5 8 Adj Pipe Alternate Horizontal Termination Caps Part Description 1208B 6 Pipe Length Black 1207B 9 Pipe Length Black 1206 12 Pipe Length Galv 1206B 12 Pipe Length Black 1204 24 Pipe Length Galv 1204B 24 Pipe Length Black 1203 36 Pipe ...

Page 14: ...t use optional flue adapter Part 370 994 when using Simpson Dura Vent pipe Refer to page 13 Simpson Dura Vent 5 inner diameter 8 outer diameter Regency Flex Vent 5 inner diameter 8 outer diameter Maintain clearances to combustibles as listed on pages 6 to 9 Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard sho...

Page 15: ...Max D 4 Max 7 Min 7 Max E 5 Max 9 Min 8 Max F 6 Max 11 Min 9 Max With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 9 feet total horizontal Please note min 1 foot between 90o elbows is required With these options max total pipe length is 30 feet with min of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is...

Page 16: ...e length is 30 feet with min of 6 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is re quired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min With these options max total pipelengthis30feetwithmin of 6 feet total vertical and max 6 feet total horizontal Please note min 1 foot between 90o elbows is re quired One 90o ...

Page 17: ...otal vertical and max 8 feet total horizon tal Please note min 1 foot between 90o elbows is re quired Vertical Venting with Three 3 90o Elbows Option H V H H1 V V1 A 1 Max 1 Min 3 Max 3 Min B 2 Max 2 Min 4 Max 5 Min C 3 Max 3 Min 5 Max 7 Min D 4 Max 4 Min 6 Max 9 Min E 5 Max 5 Min 7 Max 11 Min With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 7 feet tot...

Page 18: ...tibles Note Must use optional flue adapter when using Simpson Dura Vent pipe Part 510 994 VENTING ARRANGEMENTS VERTICAL TERMINATIONS SIMPSON DURA VENT DIRECT VENT GS SYSTEM Propane Natural Gas The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90o elbows with Simpson Dura Vent Direct Vent GS vent systems for Propane an...

Page 19: ... diagram The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with Simpson Dura Vent Direct Vent GS vent systems for Propane and Natural Gas Maximum two 45o elbows allowed Vent must be supported at offsets Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles as listed o...

Page 20: ...tor after the unit is set in its desired location otherwise the unit will not fit through the 36 5 8 930mm high frame opening 3 Put a bead of silicone inside the outer section of the adapter and a bead of Stove Mate on the inner collar Slip the adapter over the existing inner and outer flue collar and fasten to the outer collar only with the 3 supplied screws drilling pilot holes will make this ea...

Page 21: ... You may wish to relo cate the appliance or to offset as shown in Diagram 2 to avoid cutting loadbearingmem bers 3 A Firestop spacer must be installed in the floor or ceiling of every level To install the Firestop spacer in a flat ceiling or wall cut a 11 inch 279mm square hole Frame the hole as shown in Diagram 3 and install the firestop 4 Assemble the desired lengths of pipe and elbows Ensure th...

Page 22: ...the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerline of the termination and mark wall according ly Cut a 11 279mm hole in the wall inside dimension Note A top clearance of 2 1 2 64mm and side bottom clearance of 1 1 2 38mm must be maintained except that only a 1 25mm clear ance is needed at the...

Page 23: ...ervicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement Important Always check for gas leaks with a soap and water solution or gas leak detector Do not use open flame for leak testing PILOT ADJUSTMENT P48 NG System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes 27 Max Input Rating 51 000 Btu h Min Input Rating 29 000 Btu h Supply Pressu...

Page 24: ...e panel is centered Make sure the tabs of the top bracket fit into the baffle openings refer to Diagrams 6 7 The back of the top brick panel sits on top of the bottom clips 3 Insert the back brick panel first by carefully slipping it between the back wall of the firebox and the rear log bracket refer to Diagram 2 4 Put the side panels in next Tilt them in towards the middle of the firebox and put ...

Page 25: ...the logs from the box and unwrap them The logs are fragile handle with care do not force into position 3 Line up the two holes on the underside of Log 02 88 with the 2 pins at the rear of the grate and position into place 4 Place Log 02 85 on the front left side of the burner Position the right end of the log into the pin on the burner and rest the left end of the log between the 1st grate post an...

Page 26: ... 02 88 4th Grate Post 8 Line up the hole on the underside of Log 02 84 with the pin on Log 02 86 and position the notch on the bottom of the log into the last grate post 02 84 02 83 02 86 02 88 Pin in Log Last Grate Post 02 84 02 89 02 88 02 85 02 86 Notch CAUTION DO NOT cover burner ports with embers Position the notch on the bottom of the log into the 4th grate post 9 Place Log 02 89 against the...

Page 27: ...out on the underside of the log Position the cut out onto the grate bar 11 Place Log 02 87 on the middle left side of the burner Position the bottom rear of the log against the rear tab on the left side of the grate Rest the front edge of the log in the notches on Log 02 85 02 90 02 90 02 89 02 84 02 87 02 88 02 83 02 85 Tab Notches 02 88 02 89 02 90 02 87 02 85 02 83 02 86 02 84 02 85 02 87 ...

Page 28: ...To remove the flush door reverse the above steps Diagram 1 Diagram 2 FLUSH LOUVERS 1 Install the top louver by sliding the two bracket clips into the brackets located un derneath the top of the firebox 2 Install the bottom louver by folding the lou ver down and then sliding the Bottom Lou ver bracket down onto the 2 pins on the base of the unit diagram 1 Secure with 1 screw as per diagram 2 Note T...

Page 29: ...m louvers and brackets are different OPTIONAL BAY DOOR The Bay louvers MUST be used with the Bay glass option The optional Bay door is an overlay on the flush front The standard flush door and glass must remain on the unit 1 Unhook the 2 spring loaded hooks from the bottom of the flush door 2 Hook the top of the bay door over the flush door flange and swing the bottom against the bottom flange of ...

Page 30: ...firebox side 2 Secure with 2 screws per side 3 Loosen the 3 screws in the top inside edge of the firebox 4 Slide the Finishing Trim Top over the Side Trim pieces and fit the bottom bracket slots over the screws Tighten the 3 screws to secure DOUBLE SCREEN DOOR 1 Pull out the top louver 2 Center the screen door and hook over the flush door Clip locations Clip installed on right side 3 Open the scre...

Page 31: ...ed on an interior wall Regencyoffersanoptionalprogrammablether mostat but any 250 750 millivolt rated non anticipator type thermostat that is CSA ULC or UL approved may be used CAUTION Do not connect millivolt wall thermostat wires to a 120V wire INSTALLATION Can be used with Option 2 or 3 but not both Use the Regency Remote Control Kit approved for this unit Use of other systems may void your war...

Page 32: ...the fan is not purchased with the unit it is still a good idea to hardwire the terminal block in case the fan is installed at a later date However DO NOT leave this connection live until the fan is installed Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges Ground Green Neutral Live Black Red Red Fan Thermodisc normally open Ground ON OFF Rotary Speed Contro...

Page 33: ...box Check that no wire will touch the hot surfaces Diagram 2 7 AttachtheFancontrolboxtothe BurnerON OFF control box Diagram 3 9 Attach the two control boxes to the bottom louver and tighten the 2 screws on the left side and 2 screws on the right side Secure left side with 2 screws Secure right side with 2 screws Secure the 2 boxes together with one screw Diagram 1 Diagram 2 Diagram 3 Use the clip ...

Page 34: ...rial decal Attach white label This valve has been converted from NG to LPG using SIT conversion Kit Code 0 907 202 onto the valve 13 Replace yellow Natural Gas label with red Propane label 7 Remove burner orifice with a 1 2 wrench and discard Use another wrench to hold on to the elbow behind the orifice Burner Orifice Conversion Kit Contains Qty Part Description 1 910 018 SIT Conversion Kit 50 Tur...

Page 35: ...THE GLASS FRONT IN PLACE The first fire in your stove is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time before you use it with the fan on When first operated the unit will release an odour caused by the curing of the paint the burning off of any oils remaining from manu facturing Sm...

Page 36: ... If you then smell gas STOP Follow step B in the Safety Infor mation above on this label If you don t smell gas go to the next step 3 Turn knob on gas control counter clockwise to PILOT 1 Push in the gas control knob slightly and turn clockwise to OFF Do not force 2 Turn off all electric power to the appliance if service is to be performed CAUTION Hotwhileinoperation Donottouch SevereBurnsmayresul...

Page 37: ... Make a periodic check of burner for proper position and condition Visually check the flame of the burner periodically making sure the flames are steady not lifting or floating If there is a problem call a qualified service person 5 The appliance and venting system must be inspected before use and at least annual ly by a qualified field service person to ensure that the flow of combustion and vent...

Page 38: ... s should be done by a licensed or qualified service per son GLASSREPLACEMENT In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only Replacement glass is shipped already installed into the door frame Reinstall as per Glass Door Installation on page 28 INSTALLING VALVE 1 Attach the valve to the valve bracket with the 4 m5x8 metric screws pr...

Page 39: ...nd then lift the entire assembly out Slide the burner to the left and lift out Grate Remove the screw on the left side of the burner Right Side Deflector Left Side Deflector 11 Disconnect the 2 TP wires and the 2 TH wires from the valve 12 Undo the pilot tube from the valve with a 7 16 wrench 13 Undo the quick drop out thermocouple nut on the valve with a 9mm metric wrench 14 Remove the Piezo igni...

Page 40: ...ck Panel Base Left 53 902 333 Brick Panel Base Right 370 928 Brick Panel Set Standard 54 902 334 Brick Panel Back 55 902 335 Brick Panel Left 56 902 336 Brick Panel Right 57 902 582 Brick Panel Top 370 945 Herringbone Brick Panel Set 902 364 Herringbone Brick Panel Back 902 365 Herringbone Brick Panel Left 902 366 Herringbone Brick Panel Right 902 583 Heringbone Brick Panel Top 370 901 Brick Panel...

Page 41: ...ST HEAT RELEASE DUCT KIT 42 48 49 46 24 105 106 101 20 21 21 24 27 30 28 30 29 50 23 23 22 97 98 100 99 95 96 93 89 92 90 102 91 93 94 47 38 43 35 4 3 1 8 7 9 10 6 HEAT WAVE DUCT KIT HEAT WAVE DUCT KIT DOORS LOUVERS PLEASE REFER SEPARATE SECTION 51 52 53 54 56 55 57 ...

Page 42: ...er 68 W840470 Pilot Assembly Gasket 69 904 662 27 Orifice N G 904 434 47 Orifice Propane 936 170 Orifice Gasket 75 Valve Access Plate 79 370 535 Burner Assembly 82 370 019 Burner Grate Assembly 90 910 421 Pilot ON OFF Extension Knob with Bay Front 91 910 422 HI LOW Extension Knob with Bay Front 370 930 P48 Log Set 93 902 338 Center Cross Log 94 902 339 Right Side Cross Log 95 902 340 Front Left Si...

Page 43: ...Glass Flush 138 Flush Door Frame 139 936 155 Glass Gasket Tadpole 140 948 042 Spring Hinge 370 944 Finishing Trim Black 370 946 Finishing Trim Steel 141 Trim Side Left 142 Trim Side Right 143 TrimTop 150 Flush Glass Trim 370 920 Flush Glass Trim Set Steel 370 922 Flush Glass Trim Set Gold 904 196 Magnet 370 933 Double Screen Door Complete 171 Door Frame Assembly Left 172 Door Frame Assembly Right ...

Page 44: ...ay 370 905 Bay Brick Panel Set Standard Brown 370 906 Bay Brick Panel Set Standard Red 113 370 086 Bay Door Trim Each Black 370 936 Bay Door Trim Set Gold 370 934 Bay Door Trim Set Steel 370 938 Bay Louvers Set Black 370 942 Bay Louvers Set Gold Black 370 940 Bay Louvers Set Steel Black 115 Bay Louver Assembly Top 116 Bay Louver Assembly Bottom 117 904 196 Magnet 1 round 119 370 093 Bay Door Baffl...

Page 45: ...________ ______________________________________________________ ______________________________________________________ _______________________________________________________________ ___________________________________________________________ __________________________________________________________ ____________________________________________________________ _____________________________________...

Page 46: ...________ ______________________________________________________ ______________________________________________________ _______________________________________________________________ ___________________________________________________________ __________________________________________________________ ____________________________________________________________ _____________________________________...

Page 47: ...ported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect The authorized selling dealer is responsible for all in field ser...

Page 48: ...____________________________ Printed in Canada Regency fireplace products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door Fireplace Products International Ltd is pleased to extend this Lim ited Lifetime Warranty to the original purchaser of a Regency Product See the inside back co...

Reviews: