MAINTENANCE
FAN REMOVAL
1)
Shut the power off.
2)
Open the bottom louvre door.
3)
Remove the screen door
4)
Remove the
fl
ush glass door (see p 23).
5)
Remove 2 phillips screws located in the
lower left of the unit - to release the spill
switch (see Diagrams 1 & 2).
5)
Remove 2 phillips screws located near
the base of the burner and fan on/off
switch (see Diagram 3).
6)
Move burner/fan to access and unclip
wire harness (see Diagram 4).
7)
At the back of the unit, to the left of the
fan, unclip the fan ground wire clip (see
Diagram 5).
9)
Lift the fan off the 2 mounting pins (see
Diagram 7).
10)
Bring the fan to the front of the unit by
manuevering it out on an angle (see Diagram
8).
10)
Remove thermodisc by sliding it out
from the thermodisc bracket (see Diagrams
9 &10).
12)
If terminal wires need to be removed
for servicing make note of locations before
removing (see Diagram 11).
13)
Reverse steps to reinstall.
8)
Remove 11/32 (8.7mm) hex head ground
lug, to release fan ground wire (see Diagram
6).
Ground lug is located on on lower left wall of
the unit.
Spill Switch
Diagram 2
Diagram 1
Diagram 3
Wire Harness
Diagram 4
Diagram 5
Diagram 6
Diagram 7
Diagram 11
Blue=Neutral
Black=High
Red=Low
Diagram 8
Diagram 9
Thermodisc
Diagram 10