P36-5 Gas Log Fireplace
26
OPERATING INSTRUCTIONS
OPERATING
INSTRUCTIONS
1)
Read and understand these instructions
before operating this appliance.
2)
Check to see that all wiring is correct and
enclosed to prevent possible shock.
3)
Check to ensure there are no gas leaks.
4)
Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
5)
Verify that the flueing and cap are
unobstructed.
6)
Ensure that the brick panels are installed.
7)
Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8)
The unit should never be turned off, and on
again without a minimum of a 60 second
wait.
FAN
240 Volt AC power is needed for the fan switch
and blower. The fan can be hard wired if desired.
A terminal block is provided on the left hand side
of the unit. A three wire power cord can also be
used and plugged into a suitable receptacle.
Unit must be grounded at all times. Do
not cut the ground terminal off under any
circumstances.
Note: A 240 Volt AC power cord can be
installed at rough-in stage so that
the power is available. A three wire
power cord can be used.
Note: The bearings are lubricated for life.
Do not lubricate them. Make sure
you vacuum the fan area on a regular
basis.
IMPORTANT:
These fans collect a lot of dust from within
your home. Ensure you maintain these fan
motors on a regular basis by vacuuming
out the fan blades and housing using a soft
brush nozzle.