AERATION
ADJUSTMENT
The air shutter can be adjusted by moving the
adjusting wire up or down. The wire is accessed
through the bottom louver opening. Open the air
shutter for a blue flame or close for a yellower
flame. The burner aeration is factory set but
may need adjusting due to either the local gas
supply or altitude.
Minimum Air Shutter Opening:
3/16"
Natural Gas
3/8" Propane
CAUTION:
Carbon will be produced if air shutter
is closed too much.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
Closed - Tall yellow
Open - Short Blue
Note: Aeration Adjustment should only be
performed by an authorized Regency
®
Installer at the time of installation or
service.
Adjustment Wire - Push to close or
pull to open aeration cap.
OPERATING
INSTRUCTIONS
1)
Read and understand these instructions
before operating this appliance.
2)
Check to see that all wiring is correct and
enclosed to prevent possible shock.
3)
Check to ensure there are no gas leaks.
4)
Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
5)
Verify that the venting and cap are
unobstructed.
6)
Ensure that the brick panels, if used, are
installed.
7)
Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8)
The unit should never be turned off, and on
again without a minimum of a 60 second wait.
9)
Hook up remote receiver to wire marked
'receiver' which will be located on the bottom
of the appliance. This remote control requires
coding. See remote control instructions for
details.
NOTE:
This appliance will operate during power
outages. Only the fan will not operate until
power is restored. If the remote batteries in
both the handheld transmitter or receiver lose
power, the appliance can still be operated by
sliding the switch on the receiver switch from
"Remote" to "ON". To turn on the appliance
off slide the receiver switch from "ON" to
"Remote" or "OFF".
IMPORTANT:
The remote control system sup-
plied with this appliance has several options
for starting/operating the appliance, please
read the remote control operating instructions
(packed with remote control) to understand
how to operate this remote system. Option
to download remote functions video with QR
code below.
Proflame
video
LIGHTING
PROCEDURE
Important: If the pilot does not hold, turn pilot knob
to "OFF" position. Wait 5 minutes to clear gas. If
you smell gas - STOP! Follow the safety information
above. If you don't smell gas, repeat Steps 1-6.
1. Push in gas control knob slightly and turn
to "PILOT" position.
2. Push in control knob all the way and hold in
until the pilot lights up. Continue to hold the
control knob in for about 20 seconds after
the pilot is lit. Release knob.
3. Push in gas control knob slightly and turn
to "ON" position.
4. Ensure the receiver is in the remote posi-
tion.
IMPORTANT
Prior to igniting or re igniting
the pilot, remove the glass
door.
Set Switch to
Remote
Diagram 1
5. Press and release the ON/OFF button
on the remote handheld transmitter. An
audible beep should be heard from the
receiver.
ON/OFF
Button
Diagram 2
Remote shown in Manual Mode on Hi
SHUTDOWN
PROCEDURE
1
. Press "OFF" on the remote or slide receiver
switch from remote to "OFF".
2
. Turn the gas control knob to the "OFF" position
to turn off the pilot.
Pilot may be shut off during prolonged non use
periods to conserve fuel.
6.
The unit will turn on.