CGV60 user guide
|
13
user guide
To Turn Off Gas Appliance
To Turn Off Gas Appliance
Automatic Shut Off
•
Press the
OFF
button on the remote to shut off the appliance
•
Place ON/OFF switch, located on the appliance in the (O) OFF position.
•
If service is to be performed—the power must be disconnected and the gas to the unit must
be shut off.
6 Hour no Communication Function
(CSA version)
•
Manual Mode/Temperature/Timer Mode: the valve will turn to pilot flame if there is no
change in flame height for a 6 hour period. In Temperature/Timer Mode if the ambient room
temperature changes, the flame height will adjust automatically to maintain set tempera-
ture, and the fire will continue to function normally. The valve will turn to pilot flame if the set
temperature and the ambient room temperature remain the same over a 6 hour period.
Receiver Overheating
(Only if module is connected)
•
Valve turns to pilot flame if the temperature in the receiver is higher than 140
º
F /(60
º
C). the
main burner comes back on only when the temperature is below 40
º
F/ (60
º
C).
Low Battery Receiver
With low battery power in the receiver the system shuts off the fire completely. This will not hap-
pen if the power supply is interrupted.
Five Day Shut Off
(CSA version)
•
The system shuts off the fire completely if there is no change in flame height for 5 days.