MAINTENANCE
1)
Remove the exterior brick panels.
2)
Remove the glass door.
VALVE TRAY REPLACEMENT
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
b.
Swing the door out from the top and release
the hinges on the left and right side of the
door by lifting them up.
Hinge
Door
Latch
Latch Location
c. Place the door on a soft surface to prevent
scratching.
Heat
Shield
3)
Loosen the 2 screws that hold the left side
heat shield in place.
4)
Lift up and pull out the heat shield slightly
to clear the screwheads and then hang it
on the top bracket (located directly above
the heat shield).
Bracket
Heat
Shield
5) Unplug the power source.
6)
Remove the log set.
7)
Remove the interior brick panels.
8)
Remove the grate by undoing the 2 screws
on the right and left side.
9)
Remove the front burner by removing the
screw.
10)
Remove the back burner by removing the
screw.
11)
Remove the rear log stand by removing
the 4 screws.
Rear Log Stand
MAINTENANCE
Grate
Front Burner
Front Burner Removed
Back Burner
Summary of Contents for Liberty L676