MAINTENANCE
MAINTENANCE
6)
Cut the cable tie that is holds the wires
connected to the control module.
7)
Disconnect the 3 connectors from the
control module.
8)
Pull out the control module.
NOTE: The control module is held in place
with velcro.
1)
Remove the exterior brick panels.
2)
Remove the glass door.
3)
Loosen the 2 screws that hold the left side
heat shield in place.
4)
Lift up and pull out the heat shield slightly
to clear the screwheads and then hang it
on the top bracket (located directly above
the heat shield).
Control Module
9)
Replace the control module
10)
Reverse steps to re-install.
CONTROL MODULE REPLACEMENT
5)
Unplug the power source.
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
b.
Swing the door out from the top and release
the hinges on the left and right side of the
door by lifting them up.
Hinge
Door
Latch
Latch Location
Heat
Shield
Bracket
Heat
Shield