background image

 

Regency Horizon™ HZ42STE-10 Gas Fireplace

  |     

33

33

installation

Vertical Venting with Three (3) 90

o

 Elbows

Vertical Venting with Three (3) 90

o

 Elbows

           

 Option       H 

    V 

H + H1    V + V1

 

A) 

1' Max.  1' Min.  3' Max.  3' Min.

 

B) 

2' Max.  2' Min.    4' Max.  5' Min.

 

C) 

3' Max.  3' Min.'   5' Max.  7' Min.

 

D) 

4' Max.  4' Min.   6' Max.  9' Min.

 

E) 

5' Max.  5' Min.  7' Max.  11' Min.

One 90

o

 elbow = Two 45

o

 elbows.

One 90

o

 elbow = Two 45

o

 elbows.

With these options, max. total 

pipe length is 30 feet with min. 

of 11 feet total vertical and 

max. 7 feet total horizontal.

Please note min. 1 foot 

between 90

o

 elbows is 

required.

 

Option        V 

H + H1  V + V1

 

     A) 

2' Min.  3' Max.  4' Min.

 

     B) 

3' Min.  4' Max.  6' Min.

 

     C)  4' Min.  5' Max.  7' Min.

 

     D)  5' Min.  6' Max.  8' Min.

 

     E) 

6' Min.  7' Max.  9' Min.

 

     F) 

7' Min.  8' Max.  10' Min.

 

With these options, max. total 

pipe length is 30 feet with min. 

of 10 feet total vertical and 

max. 8 feet total horizontal.

Please note min. 1 foot 

between 90

o

 elbows is 

required.

Restrictor Position - Set 0  (factory setting)

Restrictor Position - Set 0  (factory setting)

Summary of Contents for HZ42STE

Page 1: ... gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach you gas supplier cal...

Page 2: ...he warmth and charm of a fireplace at the flick of a switch The model HZ42STE has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace...

Page 3: ...allation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wir...

Page 4: ...gid Pipe 4 x 6 5 8 28 Vertical terminations 31 Rigid Pipe 4 x 6 5 8 31 Vertical Terminations 32 Rigid Pipe 4 x 6 5 8 32 Unit Installation with Horizontal Termination 34 4 x 6 5 8 venting 34 Unit Installation with Horizontal Termination 35 Unit installation with Vertical Termination 36 4 x 6 5 8 venting 36 High Elevation 37 Gas Line Installation 37 Pilot Adjustment 37 Gas Pipe Pressure Testing 37 8...

Page 5: ...the unit is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts FortheStateofMassachusetts flexiblecon nectorsshallnotexceed36inchesinlength For the State of Massachusetts the appli ances individual manual shut off must be a t handle type valve The State of Massachusetts requires the installatio...

Page 6: ...rectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspe...

Page 7: ...Regency Horizon HZ42STE 10 Gas Fireplace 7 7 dimensions UNIT DIMENSIONS 1092mm 972mm 522mm 902mm 318mm 388mm 15 1 4 Inner Outer Faceplate 4 Piece Faceplate Verona Surround ...

Page 8: ...quires common sense however we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following GENERAL SAFETY INFORMATION 1 The appliance installation must conform with localcodesor intheabsenceoflocalcodes with the current Canadian or National Gas Codes CAN1 B149orANSIZ223 1InstallationCodes 2 The appliance when installed must be electri cally grounded in accor...

Page 9: ... Panels d Inner door Frame e Faceplate f Remote Control or Wall Thermostat 12 Final check Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly and operation fully explained to customer LOCATING YOUR GAS FIREPLACE 1 When selecting a location for your fireplace ensure that the clearances are met as outlined in the Clearances section 2 Provide ad...

Page 10: ... It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions F B C Installed Close to Ceiling Flue Clearances to Combustibles Horizontal Top 3 Horiztonal Side 2 Horiztonal Bottom 2 Vertical 2 Passing through wall floor ceiling when firestop is used 1 1 2 F B E D A Installed Close to Floor G Clearance Dimension Measured From A Mantel ...

Page 11: ...tc example framing 20 if 2 thick finishing material is used on both sides 16 Note Gas hookup is on vent side of unit C L C L 3 mm 6 914 Min height Flex or Rigid center of hole IMPORTANT 1 2 gap required between faceplate and finished wall Dangerous operating conditions will occur if this is not adhered to B C A Finished Floor H Steel studs on edge 41 1041mm 8 1 2 216mm 25 1 2 648mm 33 838mm C B St...

Page 12: ...cally higher than would be acceptable for combustible materials Your Regency Horizon Fireplace is no exception to this rule Therefore the units are specified with non combustible required materials to specific dimensions above and around the units This is due to these areas reaching higher temperature levels than required acceptable for a combustible material To obtain the best most durable finish...

Page 13: ...nt on whether unit is horizontally vertically vented The non combustible material comes in 3 separate pieces top section is 57 3 4 x 9 side sections are 9 x 17 53 3 4 17 39 3 4 17 7 7 8 42 Non combustible material supplied Combustible material not supplied ie Drywall 57 3 4 17 39 3 4 17 9 9 8 42 Non combustible material supplied Combustible material not supplied ie Drywall VERTICAL VENTING HORIZON...

Page 14: ...ue to the adapter and venting pushingtheunitawayfromthewall Clearance to 1 1 2 mantel leg mantel increases to 9 Clearance to 4 mantel leg increases to 13 Clearance to a 7 mantel leg increases to 16 inches Important Determinethewallthicknessprior to framing this unit The finished wall depending on thickness would decrease the required clearanceof7or9inchesdepend ing if this is horizontally vented V...

Page 15: ...is beyond 3 FRAMING FINISHING 1 Frame in the enclosure for the unit with framing material IMPORTANT Vertical studs and the header must be metal Note Depending on the material used for finishing the nailing strips must be set accordingly so that the finished material is always at the 3 edge of the flange 4 If material such as brick stone etc extends past the faceplate depth when finishing around th...

Page 16: ...eplace side line up 3 Attach the standoff securely to the side with 2 screws per standoff on opposite corners Nailing Strips shown folded out IMPORTANT NOTE Framing depth measurement is noted with the side nailing strips set as far forward on the firebox as possible The nailing strips can be adjusted back up to 3 to allow for varying thicknesses in non combustible material wall finishes INSTALLATI...

Page 17: ... finishing material per side 16 inches framing width 1 Assemble the 2 two vertical ends V of the framing kit by securing hori zontal studs H with 4 four screws securing each stud two on each side The horizontal studs H are adjustable in 1 2 increments to accommodate finishing materials determine the thickness of the finishing materials before securing the horizontal studs H 3 If installing the uni...

Page 18: ...l studs on either side of the unit as shown with 2 two screws on each end Side Supports Thin Vertical Studs Stud 8 Install 1 stud in the location shown below with 2 two screws on each side 9 Proceed with the installation of non combustible and finishing materials Wide Studs 5 Install the 2 long horizontal studs secure with 2 screws on each end if installing with horizontal vent exit see Step 4 bef...

Page 19: ...the firebox Slide the deflector out from under the nailing strip and lift the extender up off the nailing strip 2 Removethe3screwsneartheventoutletonthefirebox asshownbelow 3 Install the deflector near the vent outlet secure with the same 3 screws Ensure flange on deflector is facing downward 4 Install the extender on top of the deflector with 2 screws slide the extender until it touches the outsi...

Page 20: ...back of junction box 3 Connect the 12 pin connector to the back of the receiver 4 Install the Receiver in the Low Voltage Junction box 5 Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the Receiver switch in the OFF position to allow correct lineup for slider switch 8 Make sure the Receiver and cover plate words ON a...

Page 21: ...nts diagrams refer to the following instructions 1 Remove the glass door 2 Remove the screws that hold the vent restrictor plate in place 3 Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown 4 Once the vent restrictor plate is in the required position secure with screws VENT RESTRICTOR POSITION 3 4 1 1 4 2 1 2 3 SET 0 FACTORY SET THIS HOLE SETS THE ...

Page 22: ...xtended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on publ...

Page 23: ...le Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB Extension Pipe 16 Galvanized 46DVA 16A N A N A N A N A N A Extension Pipe 16 Black 46DVA 16AB N A N A N A...

Page 24: ...rmination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional f...

Page 25: ...for direct horizontal runs with horizontal termination use only one 45º elbow Note Must use optional rigid pipe adapter Part 510 994 when using Rigid Pipe Venting Systems VENT RESTRICTOR SETTING Vent restrictor factory set no adjustment required unless otherwise indicated Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting of Set ...

Page 26: ... flexible outer liner Kit length 2 4 flexible inner liner Kit length 3 spring spacers 4 thimble 5 AstroCap termination cap 6 screws 7 tube of Mill Pac 8 plated screws 9 S S screws 8 x 1 1 2 drill point 946 515 4 Feet 946 516 10 Feet HORIZONTAL TERMINATIONS FLEX VENT 4 X 6 5 8 These venting systems in combination with the HZ42STE Direct Vent Gas Fireplace has been tested and listed as a direct vent...

Page 27: ...ng Rigid Vent other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction withDuraventDirect Vent SelkirkDirect Temp AmeriVentDirect ICCExcel MetaFabventing and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Int...

Page 28: ... Min 7 Max E 5 Max 9 Min 8 Max F 6 Max 11 Min 9 Max Restrictor Position Set 0 factory setting Restrictor Position Set 0 factory setting HORIZONTAL TERMINATIONS RIGID PIPE 4 X 6 5 8 The diagrams below shows examples of horizontal termination arrangements using one two or three 90o elbows two 45o elbows equal one 90o elbow 1 A maximum of three 90o elbows are permitted not including the starting 45o ...

Page 29: ...n 2 Max 4 Min 5 Max C 4 Min 3 Max 6 Min 6 Max D 5 Min 4 Max 8 Min 7 Max E 6 Min 5 Max 10 Min 8 Max F 7 Min 6 Max 12 Min 9 Max Restrictor Position Set 0 factory setting Horizontal Venting with Two 2 90o Elbows One 90o elbow Two 45o elbows Option H V H H1 With these options maximum total pipe length is 30 feet with minimum of 8 feet total vertical and maximum 8 feet total horizontal Please note mini...

Page 30: ...AL TERMINATIONS The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using one 90o elbows with Rigid Pipe Venting Systems for Natural Gas Two 45o elbows equal to one 90o elbow Maximum of two 45o elbows allowed not including the starting 45o off the collar Please note min 1 foot horizontal required before 90o elbow No back to back ...

Page 31: ...well as Simpson Dura Vent Direct Vent American Metal Products Ameri Vent Direct Vent Security Secure Vent ICC Excel Selkirk Direct Temp AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent are registered and or proprietary trademarks of Simpson Dura Vent Co Inc Roof Pitch Minimum Vent Height Feet Meters flat to 7 12 2 0 61 over 7 12 to 8 12 2 ...

Page 32: ...l pipe length is 30 feet with minimum of 6 feet total vertical and maximum 6 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Restrictor Position Set 0 factory setting Restrictor Position Set 0 factory setting VERTICAL TERMINATIONS RIGID PIPE 4 X 6 5 8 Two 45o elbows equal to one 90o elbow Maximum ...

Page 33: ... these options max total pipe length is 30 feet with min of 11 feet total vertical and max 7 feet total horizontal Please note min 1 foot between 90o elbows is required Option V H H1 V V1 A 2 Min 3 Max 4 Min B 3 Min 4 Max 6 Min C 4 Min 5 Max 7 Min D 5 Min 6 Max 8 Min E 6 Min 7 Max 9 Min F 7 Min 8 Max 10 Min Withtheseoptions max total pipelengthis30feetwithmin of 10 feet total vertical and max 8 fe...

Page 34: ...ied screws drilling pilot holes will make this easier 4 Levelthefireplaceandfastenittotheframing using nails or screws through the top and side nailing strips Diagram 1 Note For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issue...

Page 35: ...r and can be adjusted for 2 x 4 or 2 x 6 walls 5 Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up there are markings on the cap to show which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the 4 supplied screws 6 Pull the centre inner and outer flex liner ...

Page 36: ... the fully twist locked position and sealed 5 Cut a hole in the roof centered on the small drilledholeplacedintheroofinStep2 Thehole shouldbeofsufficientsizetomeettheminimum requirements for clearance to combustibles of 1 1 2 Slip the flashing under the shingles shingles should overlap half the flashing as per Diagram 3 6 Continue to assemble pipe lengths Note If an offset is necessary in the atti...

Page 37: ...lting from improperly setting the aeration controlsisNOTcoveredunderwarranty GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa Disconnect piping from valve at pressures over 1 2 psig The manifo...

Page 38: ...This heater does not require a 120V A C supply for operation but it is highly recommended to install the supplied AC adaptor to eliminate the need for batteries In case of a power failure the remote control will continue to operate if batteries are installed in the receiver However a 120V A C power supply is needed for the AC adaptor Do not cut the ground terminal off under any circumstances Profl...

Page 39: ...wires neatly underneath the firebox inside the fireplace Note Ensure that wires do not touch the underside of the fire box Keep wires away from heat as much as possible AC adaptor Wire adaptor 1 AC POWER ADAPTOR INSTALLATION FOR SUREFIRE SYSTEMS OPTIONAL WALL THERMOSTAT A wall thermostat may be installed if desired connect the wires as per the wiring diagram Use table below to determine the maximu...

Page 40: ...rient the panel with the folds facing the wall of the firebox The thin unfolded edge should be facing down towards the floor of the firebox 5 Slide the panel in between the side wall of the firebox and the panel clip adhere to all handling instructions Thin edge faces downward Panel Clip Fold facing in Thin edge facing down Black Enamel Panels Black Enamel panels must be inspected for scratches an...

Page 41: ... Glass 25 Volcanic Stones 2 lb Beads 30 Ceramic Stones or 2 lb Bead 25 Volcanic Stones NOTE Glass Crystals are not supplied with the unit Must purchase separately see quantities above OPTIONAL PEBBLES GLASS CRYSTAL INSTALLATION FOR FIREBOX BASE AROUND BURNER Firebox Around Burner Packages Unit Glass Crystals Fire Beads Pebbles HZ42STE 5 lbs 5 lbs 2 packages 6 x bags pebbles There are 2 optional pa...

Page 42: ...s and flush glass doors see unit manual 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into position 4 Ensure glass crystals are installed on the burner HZ42STE 2lbs 5 Locate and install paper templates on both sides of firebox base as shown below Front and back paper templates in position 6 Install Log 1 on the far left side of the...

Page 43: ...ust aeration see unit manual for setting 15 Reverse Steps 2 and 1 8 Install on burner use template to determine the final position 9 Repeat the procedures in Steps 7 and 8 to assemble and install Logs 5 6 on the other side of the unit 10 Install Log 7 line up pin locator with pin on Log 3 as shown below Line up other end of Log 7 with template 11 Install Log 8 line up pin locator with pin on Log 5...

Page 44: ... door simply hook the top door flange onto the top of the unit and swing the door towards the unit Diagram 1 Note Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit See Diagram 2 2 With the door in proper position secure with 3 screws in locations shown in Diagram 3 Diagram 2 Diagram 3 Diagram ...

Page 45: ...y screen by bending in 6 tabs in locations shown below 4 Hook the outer door frame 3 and safety screen assembly 2 over the inner door trim 1 5 Bend the center tab up and secure with a screw to attach the outer frame safety screen assembly to the inner door trim 6 Attach completed assembly to the glass door on unit 7 Secure the assembly with 1 screw on each side 2 3 Tabs 2 Remove screws from inner ...

Page 46: ...ounting slot the one closest to the door frame overlay out of the 3 so that the faceplate and door frame overlay are flush with one another NOTE There are 3 mounting slots available this is to accommodate any finishing that protrudes slightly beyond the faceplate Tab on Faceplate Bracket in Unit Note Inner door frame may be installed by itself or with the outer door frame The outer door frame cann...

Page 47: ... 2 4 HZ42STE 10 ONLY repeat Steps 1 3 to install faceplate on other side HZ40E HZ42STE 3 76mm 3 76mm VERONA 4 PIECE FACEPLATE INSTALLATION Important 1 2 gap required between faceplate and finished wall 1 When installing required Safety Screen See Safety Screen instal lation instructions 2 Install brackets onto the back of the faceplate 3 screws for each bracket in locations shown below Hook bracke...

Page 48: ...quire cleaning NOTE Whentheglassiscoldandtheappliance is lit it may cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT DO NOT BURN THE UNIT WITHOUT THE GLASS DOOR IN PLACE FIRST FIRE NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds f...

Page 49: ...t approximately 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press ON ...

Page 50: ...er service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matériels Reportez vous au manuel du propriétaire de l inf...

Page 51: ...ollows 1 ChecktheVentingSystemforcorrosioninareas that are exposed to the elements These will appearasrustspotsorstreaks andinextreme cases holes These components should be replaced immediately 2 Remove the Cap and shine a flashlight down the Vent Remove any bird nests or other foreign material 3 Checkforevidencesofexcessivecondensation such as water droplets forming in the inner liner and subsequ...

Page 52: ...ety screen and glass door see details in this manual 4 Remove bottom cover by lifting up and out 5 Remove burner by removing 2 screws 6 Slide burner away from the pilot and lift out Aerial View of the burner shown ON OFF Connector Wires 7 Remove 7 screws to remove left access panel 8 Disconnect the ON OFF connector wires from the valve 9 Remove 7 screws to remove right side access panel Disconnect...

Page 53: ...ireplace 53 53 maintenance 11 Disconnect the inlet gas line and remove the valve assembly 12 Replace the valve assembly and reverse steps 2 11 10 Remove the valve assembly by removing the remaining 5 screws on the left side X X X X X ...

Page 54: ...arness Incl IP CP switch 8 904 593 Orifice 40 NG 904 345 Orifice 53 LP 910 100 Pilot Orifice NG 910 101 Pilot Orifice LP 911 137 Pilot Hood Clip 910 572 Remote receiver 911 127 Remote Receiver Battery Compartment 910 592 Remote Control GTMF Handheld 911 032 Remote Wire Harness 946 721 AC Adapter 911 012 DFC Digital Fireplace Control Part Description 10 258 001 Inner Door Trim 11 258 012 Safety Scr...

Page 55: ... Inner Door Frame Stainless 256 951 Verona Glass Surround Pure Black 256 955 VeronaGlassSurroundChocolateBrown Part Description 5 pound bag of glass crystals 946 775 Black Reflective Crystals 946 776 Copper Crystals 946 777 Starfire Crystals 5 pounds bag of Fire Beads 946 739 Black 946 740 Sangria Luster 946 741 Glacier Ice 946 742 Caramel Luster 946 672 Natural River Pebbles 946 674 Ceramic Spa S...

Page 56: ...56 Regency Horizon HZ42STE 10 Gas Fireplace 56 notes ...

Page 57: ...Regency Horizon HZ42STE 10 Gas Fireplace 57 57 notes ...

Page 58: ...58 Regency Horizon HZ42STE 10 Gas Fireplace 58 notes ...

Page 59: ...part be returned to the distributor or agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of Regency to charge for larger higher priced re...

Page 60: ...__________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and special offers on related products Printed in...

Reviews: