OPTIONAL FRAMING KIT
919-505
02.13.15
1
HZ42STE
58"- Vertical Vent
54"- Horizontal Vent
42"
Horizontal Exit Vent
Installation Only:
Use inner holes
on top horizon-
tal studs–cut off
excess from each
end before securing
frame to the wall
Cut here
An optional framing kit is available for the HZ42STE.
Note:
There are different confi gurations for horizontal exit venting vs vertical
exit venting and options in the framing width to accommodate various thick-
nesses of fi nishing materials.
Determine your installation prior to assembly of this frame kit.
Prior to assembling the framing kit, determine the overall thickness of the
non combustible material plus fi nishing material. Framing must be 20 inches
minus the overall non combustible/fi nishing material.
Example= 2 inches of fi nishing material per side = 16 inches framing width.
1
. Assemble the 2 (two) vertical ends (
V
) of the framing kit by securing hori-
zontal studs (
H
) with 4 (four) screws securing each stud–two on each side.
The horizontal studs (
H
) are adjustable in 1/2" increments to accommodate
fi nishing materials - determine the thickness of the fi nishing materials before
securing the horizontal studs
(H)
..
3.
If installing the unit with horizontal venting–secure the 2 (two) top horizontal
studs using the inner holes–cut the remainder of the stud (repeat at other
end) before proceeding to Step 3.
OPTIONAL FRAMING KIT
2
Install the 2 long horizontal studs, secure with 2 screws on each end - if
installing with horizontal vent exit see Step 4 before installing.
4.
Install 2 top horizontal studs with 2 screws on each side.
V
V
H
H
V
V
H
H
H
Cross Center Horizontal
studs are adjustable in
1/2" increments.
Vertical Side
20" minus 2X
fi nishing material
Vertical Exit
Vent Install–use
these holes (on
both sides)
58"- Vertical Vent
54"- Horizontal Vent
42"
Horizontal Studs
H