HZ42 Regency Horizon
TM
Gas Fireplace
38
INST
ALLA
TION
INSTALLATION
4)
Remove one screw securing the socket end of the diffuser and
separate the 2 parts - as shown below.
3)
Pull out light diffuser.
21)
Repeat steps 12-20 to install 2nd light diffuser .
22)
Plug light assembly into receptacle located in the lower left corner
inside the unit, attach ground wire to ground lug - located forward of
the receptacle.
23)
Reconnect electrical supply - test lights.
24)
Reverse steps 8 -2.
Ground
Receptacle
BULB REPLACEMENT
1)
Slide out bottom faceplate panel - see step 3 from previous page.
2)
Remove 4 screws securing light diffuser mounting plate.
6)
Reverse steps 3 through 1..
5)
Replace bulb.
Note
: Oils from hands will shorten the life of the bulbs,
do not handle bulbs with bare hands.
19)
Install socket and bulb into light diffuser as shown below.
20)
Secure socket to light diffuser with one screw - as shown below.