9
Regency Horizon™ HZ30E-1 Gas Fireplace
INSTALLATION
This includes:
1)
Clocking the appliance to ensure the correct
fi ring rate (rate noted on label 14,000 Btu/h
(NG), 13,000 Btu/h (LP) after burning appliance
for 15 minutes.
2)
If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results in dam-
age is not the responsibility of the manufacturer.
INSTALLATION
CHECKLIST
1)
Locate appliance
a) Room location (Refer to "Locating Your Gas
fi replace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantle Clearances (Refer to "Mantel
Clearances" section)
d) Framing & Finishing Requirements (Refer
to "Framing & Finishing" section)
e) Venting Requirements (Refer to "Venting"
section)
2)
Position nailing strips (Refer to "Unit Assembly
Prior to Installation).
3)
Slide unit into place.
4)
Remove installation access panel.
5)
Install vent (Refer to "Venting Arrangement"
sections).
6)
Make gas connections (Refer to "Gas Line
Installation section).
7)
Make electrical connections to receptacle
supplied with unit (recommended).
8)
Install 4 AA batteries into receiver/switch box
or optional AC power adaptor.
9)
Test the pilot (Refer to "Pilot Adjustment"
section).
10)
Test Gas Pressure (Refer to "Gas Pipe Pressure
Testing" section).
11)
Install standard and optional features. Refer to
the following sections:
a)
Glass Crystals/ Optional Ceramic
Stones
b)
Optional Firebox Base Pebbles
c) Optional
Refl ective Panels
d) Optional
Fan
e) Faceplate
f)
Remote Control or Wall Thermostat
12)
Reinstall installation access panel.
13)
Wall Mounted ON/OFF Switch:
Use the toggle wall switch supplied with the
manual package. Use of a “decor” switch causes
higher resistance which is a problem on gas
fi replaces.
14)
Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly and
operation fully explained to
customer
.
LOCATING YOUR
GAS FIREPLACE
1)
When selecting a location for your fi replace,
ensure that the clearances are met.
2)
The appliance must be installed on a fl at, solid,
continuous surface For example a wood, metal
or concrete fl oor or in a raised (on the wall) ap-
plication. The appliance must be installed on
a metal or wood panel extending the full width
and depth of the appliance.
3)
The HZ30E Direct Vent Gas Fireplace can be
installed in a recessed position or framed out
into the room as in A, B, C and D.
See Diagram 1.
Diagram 1
A)
Flat on Wall
B)
Flat on Wall Corner
C)
Recessed into Wall/Alcove
D)
Corner
4)
This appliance is Listed for bedroom
installations using the standard Remote
(millivolt thermostat system). Some areas may
have further requirements, check local codes
before installation.
5)
The HZ30E Direct Vent Gas Fireplace
is approved for alcove installations, see
"Clearances" section for details.
6)
We recommend that you plan your installation
on paper using exact measurements for
clearances and fl oor protection before actually
installing this appliance. Have an authorized
inspector, dealer, or installer review your plans
before installation.
Note: For vent terminations refer to "Exterior
Vent Termination Locations" section.