FRAMING DIMENSIONS
A
B
C
D
G
H
Non-Combustible
Facing
Metal Stud (Header)
Metal Stud
on edge
F
E
I
J
K
L
Flex or Rigid Pipe
Finished Floor
Drywall or
other facing
C2
C1
Note:
All other framing may
be of wood construction.
Framing
Dimensions
Description
HZ30E
A
Framing Height
33-5/16” (946mm)
B
Framing Width
31 - 3/16" (792mm)
C
*
Framing Depth
*
C1
Horizontal Vent 14 - 1/4" (362mm)
C2
Vertical Vent, vertical rise - terminating horizonally - 19-1/2" (495mm)
D
Minimum Height to Combustibles
Rigid 35-1/2" (902mm) | Flex 32-7/8" (835mm)
E
Corner Wall Depth
40-7/8" ( 1308mm)
F
Corner Facing Wall Width
57-13/16" (1468mm)
G
Vent Centerline Height
Rigid 29-1/4" (743mm)
Flex 26-5/8" (676mm)
H
Non-combustible facing height
13-1/4” (367mm)
I
Gas Connection Opening Height
2" (51mm)
J
Gas Connection Height
3-1/4" (83mm)
K
Gas Connection Inset
4-1/8" (105mm)
L
Gas Connection Opening Width
3-1/2" (89mm)
*
Framing depth measurement is noted with the nailing strips set as far forward on the fi rebox as possible.
The nailing strips can be adjusted back up to 1-1/2” to allow for varying thicknesses in non-combustible
material & wall fi nishes.